|
This report is being submitted pursuant to the provisions of 21 cfr, part 803 (and/or part 4, as applicable).This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes, or its employees that the report constitutes an admission that the product, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H6 component codes: most relevant component code is g07002 (appropriate term/code not available) to capture no findings available due to no product returned.H6: the product was not returned to medtech orthopaedics, however photos were provided for review.The photo investigation revealed that '03.113.023, drill bit ø2.5 w/stop calibr l250/225 f/ was broken.The observed condition of the device was consistent with a random component failure that may have been caused by exposure to unintended forces.The investigation was not able to confirm the allegation of embedded device as no x-rays were provided to evaluate the condition.Since the device was not returned, a dimensional inspection cannot be performed.The overall complaint was confirmed as the observed condition of the drill bit ø2.5 w/stop calibr l250/225 f/ would contribute to the complained device issue.Based on the investigation findings, potential cause can be component failure it has been determined that no corrective and/or preventative action is proposed.There is no indication that a design or manufacturing issue has caused the complaint condition.As part of medtech orthopaedics quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Device history lot a manufacturing record evaluation was performed for the finished device.Product code: 03.113.023 lot number: 255p655 it was electronically reviewed and no nonconformances /manufacturing irregularities were identified during the manufacturing process.The product was released on: 09 jul 2021 manufacturing site: jabil bettlach if information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|