Model Number 428882
Medical Device Problem Codes Fracture (1260); Material Rupture (1546)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 12/20/2024
Type of Reportable Event Serious Injury
Event or Problem Description
The passeo-35 xeo balloon catheter was chosen for treatment of a severely calcified lesion with 90 percent stenosis degree in the posterior tibial artery (pta).During attempt of pre-dilatation, the passeo-35 xeo ruptured at 15atm.It was attempted to remove the device but the device fractured and a part of the balloon remained in patient.The patient was transferred to the operation room to remove the fractured part.Finally, patient was discharged home with no further complication.
 
Additional Manufacturer Narrative
Neither the affected device nor the angiographic material was returned.Therefore, no technical investigation on the subject could be performed.The production documentation was reviewed to establish whether a deviation from the manufacturing process could be the cause for the reported event.Review of the production documentation confirmed that the device was manufactured according to specifications and passed all in-process and final inspections.In addition to visual inspections each device is tested for air tightness by means of a pressure test and a helium leak test.We can therefore confirm that the device was delivered in a leak-proof condition.Based on the conducted investigations, no manufacturing or material related root cause could be determined.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PASSEO-35 XEO 7/80/130
Common Device Name
CATHETER, ANGIOPLASTY, PERIPHERAL, TRANSLUMINAL
Manufacturer (Section D)
BIOTRONIK AG, BUELACH, SWITZERLAND
ackerstrasse 6
buelach CH-81 80
CH  CH-8180
Manufacturer Contact
6024 jean road
lake oswego, OR 97035
8772459800
MDR Report Key21159682
Report Number1028232-2025-00198
Device Sequence Number8594597
Product Code LIT
UDI-Device Identifier07640130452534
UDI-Public(01)07640130452534(17)2705
Combination Product (Y/N)N
Initial Reporter CountryTH
PMA/510(K) Number
K222065
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,User Facility,Company Representative,Distributor
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 02/11/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number428882
Device Catalogue Number428882
Device Lot Number05243032
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/13/2025
Supplement Date Received by Manufacturer02/10/2025
Initial Report FDA Received Date01/15/2025
Supplement Report FDA Received Date02/11/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured05/31/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-