Model Number VWCA
Medical Device Problem Code Incorrect, Inadequate or Imprecise Result or Readings (1535)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/13/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device was not returned for evaluation.Without return of the unit it is not possible to determine if some damage or defect existed on the unit that could have contributed to the event.The lot number was not provided thus a device history record was not reviewed.Per hemosphere operators manual, inaccurate non-invasive measurements can be caused by factors such as excessive variations in blood pressure, poor blood circulation to the fingers, a bent or flattened finger cuff, excessive patient movement of fingers or hands, artifacts and poor signal quality, incorrect placement of finger cuff, position of finger cuff, or finger cuff too loose, and electrosurgical unit interference.Complaint histories for all reported events are reviewed against trending control limits on a monthly basis and any excursions above the control limits are assessed and documented as a part of the monthly review.
 
Event or Problem Description
It was reported that the nibp readings had a value in the 150s while the vitawave finger cuff (vwca) had readings in the 60s.The vwca was exchanged and placed on a different finger to get a proper reading.Procedure delayed for troubleshooting.Vwca was connected to a vita monitor.There were no patient injuries.Device is not available for return.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITAWAVE
Common Device Name
SYSTEM, MEASUREMENT, BLOOD-PRESSURE, NON-INVASIVE
Manufacturer (Section D)
EDWARDS LIFESCIENCES DR
parque industrial de itabo
carr. sanchez km 18.5
haina, san cristobal
DR 
Manufacturer (Section G)
EDWARDS LIFESCIENCE
1 edwards way
irvine CA 92614
Manufacturer Contact
katheryn cespedes
1 edwards way
irvine, CA 92614
9492503939
MDR Report Key21276456
Report Number2015691-2025-00579
Device Sequence Number20983991
Product Code DXN
UDI-Device Identifier00690103218893
UDI-Public00690103218893
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
PMA/510(K) Number
K230919
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 01/30/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Model NumberVWCA
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/13/2025
Initial Report FDA Received Date01/30/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-