| Model Number |
N/A |
| Medical Device Problem Code |
Activation Problem (4042)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/26/2024
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported the safety needle in picc kit malfunctioned.The safety needles were to be used the green safety cap fell off when the picc nurses picked the needles up from the kit.There was no harm to patient or staff.No other information was provided.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The manufacturer has received the sample and will be evaluated.A supplemental will be submitted with evaluation results.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The complaint of safety mechanism failure was confirmed and the cause appeared to be manufacturing-related.The product returned for evaluation was one 21ga secureloc safety introducer needle.Usage residues were observed on the sample.The green safety mechanism cannister was completely detached from the needle shaft, leaving the needle tip exposed.The metal binding component was oriented correctly within the safety housing.The safety mechanism was disassembled and reassembled on the needle.Subsequent activation of the was unsuccessful, as the safety slipped back down the needle shaft following activation.Following disassembly of the safety, the internal components were examined under a digital microscope.The inner housing appeared well formed and unremarkable.The metal binding component was measured and the fork spacing was found to be 0.03500¿, which is above the maximum specification.It appeared that the out-of-spec component within the safety mechanism contributed to the safety mechanism detachment from the needle during attempted activation, as well as functional failure during lab testing.The implicated feature is spaced during device manufacture, and appeared to have been potentially widened too far.
|
| |
|
Search Alerts/Recalls
|