• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: NOBEL BIOCARE AB GÖTEBORG NOBELACTIVE WP 5.5X15MM; ENDOSSEOUS DENTAL IMPLANT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

NOBEL BIOCARE AB GÖTEBORG NOBELACTIVE WP 5.5X15MM; ENDOSSEOUS DENTAL IMPLANT Back to Search Results
Catalog Number 37811
Medical Device Problem Code Failure to Osseointegrate (1863)
Health Effect - Clinical Code Failure of Implant (1924)
Date of Event 02/03/2024
Type of Reportable Event Serious Injury
Event or Problem Description
Failure to osseointegrate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NOBELACTIVE WP 5.5X15MM
Common Device Name
ENDOSSEOUS DENTAL IMPLANT
Manufacturer (Section D)
NOBEL BIOCARE AB GÖTEBORG
bohusgatan 15
göteborg 41139
SW  41139
Manufacturer (Section G)
NOBEL BIOCARE AB GÖTEBORG
bohusgatan 15
göteborg 41139
SW   41139
Manufacturer Contact
gayco meel
popeweg 72
venlo 5928 -SC
NL   5928 SC
623202508
MDR Report Key21350248
Report Number9611993-2025-045361
Device Sequence Number8912424
Product Code DZE
UDI-Device Identifier07332747088342
UDI-Public(01)07332747088342(10)12116504(17)230723
Combination Product (Y/N)N
Initial Reporter CountryVM
PMA/510(K) Number
K133731
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2024
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date07/23/2023
Device Catalogue Number37811
Device Lot Number12116504
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date02/10/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured08/24/2018
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age57 YR
Patient SexMale
-
-