| Catalog Number |
47530300L |
| Medical Device Problem Code |
Burst Container or Vessel (1074)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/16/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Additional information is pending and will be submitted within 30 days upon receipt.
|
| |
|
Event or Problem Description
|
|
As reported, the 3.0 x 300.014 saberx percutaneous transluminal angioplasty (pta) balloon rupture during treatment.The balloon ruptured upon initial inflation at approximately 14 to 15 atm.The balloon was removed, and the procedure was completed as planned using a new saber.014 balloon of the same size.There was no adverse event was reported.The physician was treating a chronic total occlusion (cto) in the posterior tibial (pt) artery.The device will be returned for evaluation.
|
| |
|
Additional Manufacturer Narrative
|
|
As reported, the 3.0 x 300.014 saberx percutaneous transluminal angioplasty (pta) balloon rupture during treatment.The balloon ruptured upon initial inflation at approximately 14 to 15 atm.The balloon was removed, and the procedure was completed as planned using a new saber.014 balloon of the same size.There was no adverse event was reported.The physician was treating a chronic total occlusion (cto) in the posterior tibial (pt) artery.Additional information was requested but not provided.The product was not returned for analysis.A review of the manufacturing documentation associated with lot 2306278359 presented no issues during the manufacturing process that can be related to the reported event.The reported ¿balloon burst - at/below rbp¿ could not be confirmed as the device was not returned for analysis.The exact cause could not be determined.The reported cto of the pt artery may have contributed to the reported event; it is likely to have caused damage to the balloon material that led to its rupture.However, without return of the product for analysis or films of the event it is difficult to draw a clinical conclusion between the device and the reported event.According to the warnings in the safety information in the instructions for use, ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.To reduce the potential for vessel damage or the risk of dislodgement of particles it is very important that the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the lesion.Do not exceed the rated burst pressure recommended on the label.The rated burst pressure is based on the results of in vitro testing.Use of a pressure monitoring device is recommended to prevent over-pressurization.Pressure in excess of the rated burst pressure can cause balloon rupture and potential inability to withdraw the catheter through the introducer sheath.Balloon rupture can cause vessel damage and the need for additional intervention.Based on the device history record review, there is no indication that the event is related to the device design or manufacturing process.Therefore, no preventative or corrective actions will be taken at this time.
|
| |
|
Event or Problem Description
|
|
As reported, the 3.0 x 300.014 saberx percutaneous transluminal angioplasty (pta) balloon rupture during treatment.The balloon ruptured upon initial inflation at approximately 14 to 15 atm.The balloon was removed, and the procedure was completed as planned using a new saber.014 balloon of the same size.There was no adverse event was reported.The physician was treating a chronic total occlusion (cto) in the posterior tibial (pt) artery.The device will be returned for evaluation.
|
| |
|