| Model Number |
G154 |
| Medical Device Problem Code |
High impedance (1291)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
12/08/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that this cardiac resynchronization therapy defibrillator (crt-d) system exhibited high out of range shock lead impedances measuring above 200 ohms.Technical services (ts) was consulted, and further in office review was recommended.No adverse patient effects were reported.This system remains in service.
|
| |
|
Event or Problem Description
|
|
It was reported that this cardiac resynchronization therapy defibrillator (crt-d) system exhibited high out of range shock lead impedances measuring above 200 ohms.Technical services (ts) was consulted, and further in office review was recommended.No adverse patient effects were reported.This system remains in service.Additional information was received indicating that this device was subsequently explanted and replaced.No additional adverse patient effects were reported.This device has been returned.
|
| |
|
Event or Problem Description
|
|
It was reported that this cardiac resynchronization therapy defibrillator (crt-d) system exhibited high out of range shock lead impedances measuring above 200 ohms.Technical services (ts) was consulted, and further in office review was recommended.No adverse patient effects were reported.This system remains in service additional information was received indicating that this device was subsequently explanted and replaced.No additional adverse patient effects were reported.This device has been returned.
|
| |
|
Additional Manufacturer Narrative
|
|
The returned device was thoroughly inspected and analyzed upon receipt at our post market quality assurance laboratory.Visual examination of the device header and case noted no anomalies.Dimensional analysis of the header was completed.Each port measured as expected.The device was then exposed to simulated heart load conditions, and the defibrillation, pacing and sensing functions were tested.Impedance testing was completed, and all measurements were within normal limits.The device operated appropriately with no interruptions in therapy output at the returned programmed settings.A series of electrical tests was also performed, and again, normal device function was observed.Analysis did not identify any device characteristics that would have caused or contributed to the reported clinical observations.
|
| |
|