Catalog Number 4825202
Medical Device Problem Codes Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/14/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation: the run data file (rdf) was analyzed for this event.The analysis of the run data file did not identify a conclusive root cause for the higher-than-expected wbc content reported in the rbc product for this collection.No unusual process variable was identified from the signals in the run data file.Based on the available information, it cannot be ruled out that the higher-than-expected wbc content in the rbc product may be donor-related.It also cannot be ruled out that the loading of the disposable set, particularly the rbc filter, may have contributed to the higher-than-expected wbc content measured in the rbc product.Investigation is in process; a follow-up report will be provided.
 
Event or Problem Description
The customer would like the run data file investigated to determine a possible cause for the elevated white blood cell (wbc) content in the in red blood cell (rbc) product.Donor unit id #: (b)(6) there was not a transfusion recipient or patient involved at the time of the residual wbc testing; therefore, no patient information is reasonably known at the time of the event.The collection set is not available for return because it was discarded by the customer.
 
Event or Problem Description
The customer would like the run data file investigated to determine a possible cause for the elevated white blood cell (wbc) content in the in red blood cell (rbc) product.Donor unit id #: (b)(6) there was not a transfusion recipient or patient involved at the time of the residual wbc testing; therefore no patient information is reasonably known at the time of the event.The collection set is not available for return because it was discarded by the customer.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in h.6 and h.11.Investigation: the run data file (rdf) was analyzed for this event.The analysis of the run data file did not identify a conclusive root cause for the higher-than-expected wbc content reported in the rbc product for this collection.No unusual process variable was identified from the signals in the run data file.Based on the available information, it cannot be ruled out that the higher-than-expected wbc content in the rbc product may be donor-related.It also cannot be ruled out that the loading of the disposable set, particularly the rbc filter, may have contributed to the higher-than-expected wbc content measured in the rbc product.The device history records (dhr) were reviewed for this lot.There were no events noted in the dhr that would have contributed to the elevated wbc count experienced by the customer.Root cause: a root cause assessment was performed for this complaint.The analysis of the run data file did not identify a conclusive root cause for the higher-than-expected wbc content reported in the rbc product for this collection.No unusual process variable was identified from the signals in the run data file.Based on the available information, it cannot be ruled out that the higher-than-expected wbc content in the rbc product may be donor-related.It also cannot be ruled out that the loading of the disposable set, particularly the rbc filter, may have contributed to the higher-than-expected wbc content measured in the rbc product.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIMA ACCEL
Common Device Name
TRIMA ACCEL AUTORBC, PLASMA SET
Manufacturer (Section D)
TRIMA ACCEL
lakewood CO 80215
Manufacturer (Section G)
TERUMO BCT
10810 w. collins ave
lakewood CO 80215
Manufacturer Contact
scot hilden
10810 w. collins ave
lakewood, CO 80215
MDR Report Key21399665
Report Number1722028-2025-00035
Device Sequence Number8316994
Product Code GKT
UDI-Device Identifier05020583825208
UDI-Public05020583825208
Combination Product (Y/N)N
Initial Reporter StateWA
Initial Reporter CountryUS
PMA/510(K) Number
BK190332
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Administrator/Supervisor
Type of Report Initial,Followup
Report Date (Section B) 02/17/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/01/2026
Device Catalogue Number4825202
Device Lot Number2406141142
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/23/2025
Supplement Date Received by Manufacturer03/03/2025
Initial Report FDA Received Date02/18/2025
Supplement Report FDA Received Date03/03/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured06/14/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-