Model Number TC301US
Medical Device Problem Code Insufficient Device Problem Information (3190)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/29/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device was returned to our us facility on (b)(6) 2025, and will later be forwarded to the manufacturing site for investigation.Should relevant additional information / investigation results become available, a supplemental medwatch report will be submitted unsolicited.This event is filed under internal complaint id (b)(6).
 
Event or Problem Description
It was reported that during a procedure (case type was not provided) on (b)(6) 2025, device had intermitting blackouts.They were able to complete the procedure with a back-up unit without any patient impact.
 
Additional Manufacturer Narrative
Per evaluation from the manufacturer: complaint verified - the camera card edge would not seat properly in the camera receptacle.A functional test confirmed the customer's complaint.The issue was caused because of a missing card edge receptacle roller pin.This roller pin became missing/dislodged because the roller pin retainer lip had broken.A visual inspection confirmed excessive amounts of contamination around the front panel near the broken roller pin receptacle.This contamination likely weakened the retainer lip causing it to break.The customer's receptacle was damaged due to contamination from improper sterilization.The entire receptacle, edac, and front panel will need to be replaced to address the customer's issue.This event is filed under internal complaint id (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CCU,MODULAR,IMAGE1 S X-LINK,US
Common Device Name
CCU,MODULAR,IMAGE1 S X-LINK,US
Manufacturer (Section D)
KARL STORZ IMAGING
1 s. los cameros road
goleta CA 93117
Manufacturer (Section G)
KARL STORZ IMAGING
1 s. los cameros road
goleta CA 93117
Manufacturer Contact
anja fair
2151 e grand ave
el segundo, CA 90245
4242188247
MDR Report Key21407222
Report Number2027009-2025-00244
Device Sequence Number15507494
Product Code FET
UDI-Device Identifier04048551356562
UDI-Public04048551356562
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K160044
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/14/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberTC301US
Device Catalogue NumberTC301US
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/06/2025
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/30/2025
Supplement Date Received by Manufacturer02/24/2025
Initial Report FDA Received Date02/19/2025
Supplement Report FDA Received Date03/14/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-