Catalog Number 53814G
Medical Device Problem Code Improper Chemical Reaction (2952)
Health Effect - Clinical Codes Pain (1994); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 02/03/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the magic 3 go male intermittent catheters were defective, grey and the lubricant was dried up.Patient also stated that the catheters were improperly sealed.They caused patient bleeding and pain and were difficult to insert.No medical intervention was reported.
 
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.Udi format updated with available product information per gudid.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Additional Manufacturer Narrative
The reported event was inconclusive because this investigation did not result in any additional findings and no sample was available for evaluation.No actions can be taken at this time since a root cause was not identified.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: caution: federal (usa) law restricts this device to sale by or on the order of a physician.Device description the magic3 go¿ intermittent urinary catheter is a silicone tube with a hydrophilic coating to be inserted into the urethra for the purpose of draining the bladder of urine.The intended clinical benefit of magic3 go¿ is the intermittent management of the bladder through urine drainage.Not made with natural rubber latex.Does not contain dehp.Indications for use the magic3 go¿ intermittent urinary catheter is intended for urological use only.It is intended for use by adult and pediatric patients of all ages for bladder management including urine drainage, collection, and measurement.The device is passed to the urinary bladder via the urethra.Intended users healthcare professionals and/or lay users.Contraindications none known.Warnings this is a single use device.Do not resterilize any portion of this device.Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient.After use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practices and applicable local, state and federal laws and regulations.Precautions do not use device if package is opened or damaged.Inspect the catheter before use.Do not use the device if damaged.Adverse reactions ¿ urinary tract infection ¿ bleeding from the urethra ¿ irritation of the urethra self-catheterization should follow the plan of care and advice given by your healthcare practitioner and be carried out only in accordance with the instructions for use provided.If you have any clinical concerns with the use of this device for your condition, please contact your healthcare physician.Instructions for use review the self-catheterization procedure with a healthcare professional.1.Always wash hands prior to use.2.Open the catheter package by gripping the white "v" notch and tearing downwards until insertion sleeve is fully exposed.3.If desired, use the adhesive label on the back of the package to hang the package on a nearby dry vertical surface while preparing to catheterize.4.Clean the opening to the urethra ¿ and the surrounding area.Wipe from front to back to avoid fecal contamination.Wash your hands again.5.Hold the insertion sleeve with your dominant hand and squeeze it to grip the catheter shaft as you remove the catheter from the pack.Next, hold the catheter funnel above the insertion sleeve with your other hand and slide the insertion sleeve down the shaft, stopping at about 6¿ from the tip.Release the funnel.Using the insertion sleeve to hold the catheter firmly, gently pass the tip of the catheter into your urethra until the insertion sleeve nears the meatus.Repeat until urine starts to flow.Note: if you are using a coudé tip catheter, the raised notch on the catheter funnel will indicate the orientation in which the tip curves upward.Ensure that the coudé indicator notch is facing upwards during insertion.6.Keep the catheter steady until urine stops flowing.When urine stops flowing, slowly withdraw the catheter, stopping if flow starts again, until the last few drops have drained.Check the color, odor and clarity of the urine.Any changes may need to be reported to a health care professional.Disposal 7.Place the catheter back into the package and dispose in accordance with accepted medical practice and applicable local, state and federal laws and regulations.Do not flush down the toilet.8.Wash hands.Correction: e udi format updated with available product information per gudid.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event or Problem Description
It was reported that the magic 3 go male intermittent catheters were defective, grey and the lubricant was dried up.Patient also stated that the catheters were improperly sealed.They caused patient bleeding and pain and were difficult to insert.No medical intervention was reported.Per customer via phone on 14apr2025, it was reported that he no longer uses the magic 3 catheters, he uses coloplast right now without any issues.He states that he returned the new boxes of the magic 3 to his supplier 180 medical.No lot number was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MAGIC3 GO MALE CATHETER WITH SUREGRIP
Common Device Name
INTERMITTENT CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
Manufacturer (Section G)
C.R. BARD INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
Manufacturer Contact
xeeroy rada
8195 industrial blvd
covington 30014
7707846100
MDR Report Key21421469
Report Number1018233-2025-01095
Device Sequence Number15401841
Product Code EZD
UDI-Device Identifier00801741136962
UDI-Public(01)00801741136962(11)240917(17)270828(10)JUJW0389
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K172247
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Consumer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 05/15/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Catalogue Number53814G
Device Lot NumberJUJW0389
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/03/2025
Supplement Date Received by Manufacturer05/16/2025
Initial Report FDA Received Date02/20/2025
Supplement Report FDA Received Date05/19/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured09/17/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexMale
-
-