• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARTHREX, INC. SUTR ANCH PEEK S-TAK KNOTLESS 3X12.7MM; BIO SOFT TISSUE FIXATN FASTNR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARTHREX, INC. SUTR ANCH PEEK S-TAK KNOTLESS 3X12.7MM; BIO SOFT TISSUE FIXATN FASTNR Back to Search Results
Model Number SUTR ANCH PEEK S-TAK KNOTLESS 3X12.7MM
Medical Device Problem Codes Use of Device Problem (1670); Failure to Advance (2524)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/07/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that during a knee capsule repair surgery the suture did not tighten.Per complaint reporter there was no harm for patient, operator or third party.The surgery was finished successfully with a new device with the same part number.It was not necessary to switch the surgical technique or do a second surgery.
 
Additional Manufacturer Narrative
Investigation is in process.A follow-up report will be provided upon availability of additional information.
 
Additional Manufacturer Narrative
Additional information: d9, g3, h3, h6.Complaint allegation is not confirmed due to the reported failure being unable to be replicated due to not receiving all components.One unpackaged ar-1938ps-1 suture anchor, peek suture tak was received for investigation.Visual evaluation of the returned device noted that the sutures and anchor were no longer assembled to the driver and not returned for investigation.Functional testing was not performed due to the missing components.The most likely cause for the reported failure can be attributed to improper suture orientation.The surgical technique for knee capsule repair outlines the proper steps in steps 6 through 11 on pages 3 & 4.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SUTR ANCH PEEK S-TAK KNOTLESS 3X12.7MM
Common Device Name
BIO SOFT TISSUE FIXATN FASTNR
Manufacturer (Section D)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer (Section G)
ARTHREX, INC.
1370 creekside boulevard
naples FL 34108 1945
Manufacturer Contact
jared engle
8009337001
MDR Report Key21424979
Report Number1220246-2025-00573
Device Sequence Number7642005
Product Code MAI
UDI-Device Identifier00888867282421
UDI-Public(01)00888867282421(11)210621(17)260531(10)13568772
Combination Product (Y/N)N
Initial Reporter CountryPL
PMA/510(K) Number
K140855
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 07/31/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/31/2026
Device Model NumberSUTR ANCH PEEK S-TAK KNOTLESS 3X12.7MM
Device Catalogue NumberAR-1938PS-1
Device Lot Number13568772
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/10/2025
Supplement Date Received by Manufacturer07/23/2025
Initial Report FDA Received Date02/20/2025
Supplement Report FDA Received Date07/31/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/21/2021
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-