MAUDE Adverse Event Report: ETHICON INC. PROCEED*SURG MESH/MULTI LYR; MESH, SURGICAL, POLYMERIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON INC. PROCEED*SURG MESH/MULTI LYR; MESH, SURGICAL, POLYMERIC Back to Search Results
Lot Number AAG059
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Abdominal Pain (1685); Nausea (1970); Vomiting (2144); Constipation (3274); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Date sent to the fda: 2/21/2025.H6: appropriate term / code not available (e2402) utilized to capture mesh had completely pulled apart from the fascia d4: udi: as the lot number for the device involved in the event was for dhr review, the full udi is currently not available.(b)(4) submitted for adverse event which occurred on 1/7/2009.(b)(4) submitted for adverse event which occurred on 2/20/2010.To date, the device has not been returned.If the product is returned for evaluation, any further information derived from the evaluation will be submitted in a supplemental 3500a form.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Event or Problem Description
It was reported by an attorney that the patient underwent hernia repair surgery on (b)(6) 2008 and mesh was implanted.It was reported that the patient underwent revision surgery on (b)(6) 2009 and mesh was implanted during which the surgeon noted that it was discovered that the entire right side of his previously placed mesh repair had completely pulled apart from the fascia.It was reported that the patient had a partial removal surgery on (b)(6) 2010.It was reported that the patient experienced abdominal pain, nausea, vomiting and constipation.No additional information was provided.
 
Additional Manufacturer Narrative
Date sent to the fda: 3/7/2025.A review of the batch manufacturing records was conducted and the batch met all finished goods release criteria.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Common Device Name
MESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON INC.-CORNELIA
655 ethicon circle
cornelia GA 30531
Manufacturer Contact
elba bello
1000 route 202
raritan, NJ 08869
9083863534
MDR Report Key21430308
Report Number2210968-2025-01879
Device Sequence Number4337175
Product Code FTL
UDI-Device Identifier10705031047709
UDI-Public(01)10705031047709(17)081223(10)AAG059
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
K060713
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2008
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 02/21/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date12/23/2008
Device Lot NumberAAG059
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 02/18/2025
Supplement Date Received by Manufacturer02/26/2025
Initial Report FDA Received Date02/21/2025
Supplement Report FDA Received Date03/07/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured01/23/2008
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexMale
-
-