• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SIEMENS HEALTHCARE DIAGNOSTICS INC. ADVIA CENTAUR XPT ANALYZER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SIEMENS HEALTHCARE DIAGNOSTICS INC. ADVIA CENTAUR XPT ANALYZER Back to Search Results
Model Number ADVIA CENTAUR XPT ANALYZER
Medical Device Problem Codes High Test Results (2457); Low Test Results (2458)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/28/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A united states (us) customer contacted a siemens customer care center (ccc) and reported that erroneous total human chorionic gonadotropin hcg (thcg) results were obtained on multiple patient samples when processed on an advia centaur xpt analyzer.Quality control (qc) and calibration were within the laboratory established ranges.A siemens customer service engineer (cse) was dispatched to the customer¿s site.During this visit, the cse decontaminated the analyzer, replaced the wash separation manifold, acid and base pumps, reagent probes 1 (r1) and 2 (r2), luminometer, vacuum regulator, and waste reservoir bottle tubing/cap.Siemens further evaluated the event and concluded that the issue with the vacuum caused the erroneous thcg results.The analyzer is performing according to specifications.No further evaluation of this device is required.
 
Event or Problem Description
The customer reported that erroneous total human chorionic gonadotropin (thcg) results were obtained on multiple patient samples when processed on an advia centaur xpt analyzer.The initial results were not reported to the physician(s).The same samples were reprocessed on the original analyzer.The repeat results were considered correct and were reported to the physician(s).There are no known reports of patient intervention or adverse health consequences due to the erroneous thcg results.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVIA CENTAUR XPT ANALYZER
Common Device Name
ADVIA CENTAUR XPT ANALYZER
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS INC.
511 benedict ave.
tarrytown NY 10591
Manufacturer (Section G)
SIEMENS HEALTHCARE DIAGNOSTICS MANUFACTURING LIMITED
chapel lane, swords, co.
registration number: 8020888
dublin
EI  
Manufacturer Contact
varsha joshi
pritech park sez, block 11
sarjapur outer ring road
karnataka 56010-3
IN   560103
870577433
MDR Report Key21557743
Report Number2432235-2025-00081
Device Sequence Number4373478
Product Code JJE
UDI-Device Identifier00630414596914
UDI-Public(01)00630414596914
Combination Product (Y/N)N
Initial Reporter StatePA
Initial Reporter CountryUS
PMA/510(K) Number
K141999
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 03/10/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberADVIA CENTAUR XPT ANALYZER
Device Catalogue Number10711433
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/13/2025
Initial Report FDA Received Date03/10/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured03/13/2017
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Patient SexUnknown
-
-