| Catalog Number |
CDHXX |
| Medical Device Problem Codes |
Adverse Event Without Identified Device or Use Problem (2993); Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Codes |
Failure to Anastomose (1028); Hemorrhage/Blood Loss/Bleeding (1888)
|
| Date of Event |
01/16/2024
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Date sent: 3/11/2025 d4: batch # unk d4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.D4: udi: the expiration date is currently not available.Therefore, the full udi is currently not available.This report is related to a journal article; therefore, no product will be returned for analysis and the batch history records cannot be reviewed as the lot/batch number has not been provided.Additional information was requested, and the following was obtained: could you please provide more details on how each issue was addressed for the following events (occur intra-operatively or post-operatively, treatment, medical or surgical interventions performed: unk_echelon circular powered stapler anastomotic complications including post operative anastomotic bleeding(n=3) anastomotic leakage (n=27) cdhxx-ils 21mm curved anastomotic complications including post operative anastomotic bleeding (n=12 anastomotic leakage (n=156) does the surgeon believe that was a result of either of the ethicon devices? unk_echelon circular powered stapler anastomotic complications including post operative anastomotic bleeding(n=3) anastomotic leakage (n=27) cdhxx-ils 21mm curved anastomotic complications including post operative anastomotic bleeding (n=12 anastomotic leakage (n=156) please provide further details.Is it known whether or not the issues noted were previously reported to ethicon customer quality? if yes, do you have the product complaint submission record numbers? no further information will be provided because we can¿t get any additional information from the author.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent: does the author/surgeon believe that the ethicon device caused or contributed to the patient complications mentioned in the article? if yes, please explain.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported via journal article: title: usefulness of a powered circular stapler compared with a manual circular stapler in patients undergoing colorectal cancer surgery: a retrospective cohort study and systematic review author: rie mizumot01,2 , norikatsu miyoshi1 ¿ 2, rie hayashi1 , shinya kato1 , soichiro minami1 , mitsunobu takeda 1 , yuki sekido1 , tsuyoshi hata 1 , atsushi hamabe1 , takayuki ogino1 , mitsuyoshitei3 , yoshinorikagawa4 , mamoruuemura1 , yuichirodoki1 and hidetoshieguchi1 citation: doi: 10.3892/ol.2024.14640.This was a single-center retrospective study.Patients undergoing radical resection and anastomosis for sigmoid colon or rectal cancer using a circular stapler.Between january 2018 and december 2022 was conducted, the study included 414 patients:(n= 231)in the manual circular stapler group and (n=183) in the powered circular stapler (pcs) group.An increased risk ratio was observed in the manual group compared with the automatic group when restricted to elderly patients.Similarly, a meta-analysis found a significantly higher anastomotic complication risk in the manual group compared with the automatic group patients in the pcs group were significantly older than those in the mcs group.Anastomotic complications are related to short-term outcomes, including the length of hospital stay and reoperation rate, and to long-term outcomes, such as disease-free survival and overall survival, because they are related to postoperative chemotherapy administration ethicon circular stapler cdh or eea circular stapler -when performed manual anastomosis by experienced gastrointestinal surgeons; used in mcs group echelon circular powered stapler -when performed automatic anastomosis by experienced gastrointestinal surgeons; pcs group reported complications: ethicon circular stapler cdh or eea circular stapler -anastomotic complications including post operative anastomotic bleeding(n=12) -anastomotic leakage (n=156) echelon circular powered stapler -anastomotic complications including post operative anastomotic bleeding(n=3) -anastomotic leakage (n=27) -reoperation case (n=1) in conclusion, a pcs may be useful for reducing the risk of anastomotic complications in patients undergoing crc surgery.
|
| |
|
Search Alerts/Recalls
|
|
|