W. L. GORE & ASSOCIATES, INC. GORE® TAG® CONFORMABLE THORACIC STENT GRAFT WITH ACTIVE CONTROL SYSTEM; SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
|
Back to Search Results |
|
| Catalog Number |
TGMR404015 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Vascular Dissection (3160)
|
| Date of Event |
02/25/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
The following details were reported to gore: on (b)(6) 2025, this patient underwent endovascular treatment for a zone 2 thoracic acute aortic dissection utilizing gore® tag® thoracic branch endoprostheses.It was reported that the gore® tag® thoracic branch endoprosthesis (aortic component) (tac083415a/(b)(6)) was advanced up to the intended location and lined up.The primary handle deployment was deployed, and the very first proximal sleeve unzipped, however the rest did not.Additionally, it was reported that both deployment strings/lines came all the way out of the graft.It was reported that the deployment string/line for the secondary deployment was believed to broken.It is unknown if it broke at the portal, or at the distal end of the graft.The physician carefully dragged the graft through the aorta down to a 22fr gore® dryseal hydro flex introducer sheath (dsf2233/(b)(6) or dsf2233/(b)(6) (dsf).The physician was able to pull the device back into the dsf (except for the proximal portion that had already been deployed open).In doing so the left common iliac artery (lcia) and a portion of the external iliac artery (lceia) suffered a dissection.Next, the physician advanced another 22fr dsf up the right groin and two gore® tag® conformable thoracic stent grafts (ctag) (tgmr373720/(b)(6) and tgmr404015/(b)(6)) were deployed to treat the zone 2 dissection with intentional coverage of the left subclavian artery (lsa) as the proximal entry tear was just distal to the lsa.The physician then treated the dissection in the lcia/lceia with a bare metal stent and viabahn® vbx balloon expandable endoprosthesis.The physician opted not to perform a bypass of the lsa but will monitor the patient.Should bypass of the lsa become necessary at a later date he will do so.The patient tolerated the procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional device(s) associated with this event include: tgmr373720/(b)(6), udi: (b)(4) w.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Search Alerts/Recalls
|
|
|