• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BIOSENSE WEBSTER INC OPTRELL MAPPING CATHETER WITH TRUEREF TECHNOLOGY; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BIOSENSE WEBSTER INC OPTRELL MAPPING CATHETER WITH TRUEREF TECHNOLOGY; CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING Back to Search Results
Catalog Number D142901
Medical Device Problem Code Obstruction of Flow (2423)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/18/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster inc., or its employees that the report constitutes an admission that the product, biosense webster inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Manufacturer's ref.# (b)(4).
 
Event or Problem Description
It was reported that a patient underwent a cardiac ablation procedure with a optrell mapping catheter with trueref technology and an infusion alarm sounded.During pre-mapping, an alarm for infusion pump blockage sounded.Although the catheter was pulled from the patient's body, straightened, and infused again outside the patient's body and transfused again, but the alarm did not stop.The issue was addressed by replacing the catheter with a new optrell but the alert occurred at the time of flushing before inserting the catheter into the patient's body.Since perfusion was achieved, continued use was permitted with the physician's approval.
 
Additional Manufacturer Narrative
On 18-mar-2025, the bwi product analysis lab received the complaint device for evaluation.The product analysis has begun but is not completed at this time.When the investigational analysis has been completed, a supplemental 3500a report will be submitted.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.# (b)(4).
 
Additional Manufacturer Narrative
It was reported that a patient underwent a cardiac ablation procedure with a optrell mapping catheter with trueref technology and an infusion alarm sounded.During pre-mapping, an alarm for infusion pump blockage sounded.Although the catheter was pulled from the patient's body, straightened, and infused again outside the patient's body and transfused again, but the alarm did not stop.The issue was addressed by replacing the catheter with a new optrell but the alert occurred at the time of flushing before inserting the catheter into the patient's body.Since perfusion was achieved, continued use was permitted with the physician's approval.Device evaluation details: the device was returned to johnson & johnson medtech (j&j medtech) for evaluation.A visual inspection and irrigation test of the returned device were performed following j&j medtech procedures.Visual analysis revealed no damage or anomalies on the device.An irrigation test was performed, and the device was flushing correctly.No irrigation issues were observed.A manufacturing record evaluation was performed for the finished device batch number, and no internal actions were identified.The issue reported by the customer could not be replicated during the product investigation; other issues or circumstances may have occurred during the usage of the device that compromised its performance.The instructions for use contain the following recommendations: flush the catheter with heparinized saline prior to insertion into the body.As part of the quality process, all devices are manufactured, inspected, and released to approved specifications.If additional information is received regarding this event, a supplemental 3500a report will be submitted to the fda.Manufacturer's ref.# (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OPTRELL MAPPING CATHETER WITH TRUEREF TECHNOLOGY
Common Device Name
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
BIOSENSE WEBSTER INC
31 technology drive, suite 200
irvine CA 92618
Manufacturer (Section G)
BIOSENSE WEBSTER INC (JUAREZ)
circuito interior norte
1820parque industrial salvacar
juarez 32599
MX   32599
Manufacturer Contact
kate karberg
31 technology dr
irvine, CA 92618
3035526892
MDR Report Key21601991
Report Number2029046-2025-00782
Device Sequence Number4375885
Product Code DRF
UDI-Device Identifier10846835025828
UDI-Public(01)10846835025828(11)240617(17)270616(10)31356780M
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K230253
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup,Followup
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberD142901
Device Lot Number31356780M
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/18/2025
Supplement Date Received by Manufacturer03/18/2025
03/21/2025
Initial Report FDA Received Date03/13/2025
Supplement Report FDA Received Date03/19/2025
03/31/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/17/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
NGEN PUMP, JAPAN CONFIGURATION; OPTRELL, 36 ELECTRODES, D-F
Patient SexUnknown
-
-