|
(b)(4).Date sent: 3/14/2025.D4: batch # unk.D4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.D4: udi: the expiration date is currently not available.Therefore, the full udi is currently not available.This report is related to a journal article, therefore no product will be returned for analysis and the batch history records cannot be reviewed as the lot/batch number has not been provided.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent: does the author/surgeon believe that the ethicon device caused or contributed to the patient complications mentioned in the article? if yes, please explain.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
|
It was reported via journal article: title: textbook outcome after gastrectomy for gastric cancer is associated with improved overall and disease-free survival.Authors: candan cetinkaya-hosgör, philippa seika, jonas raakow, dino kröll i id eva maria dobrindt, max magnus maurer, friederike martin, ramin raul ossami saidy, peter thuss-patience, johann pratschke, matthias biebl, and christian denecke.Citation: journal clinical medicine.2023 https://doi.Org/10.3390/.The aim of this study was to investigate the effect of the surgical outcome on survival and to identify patient- and procedure-related factors that predict the achievement of textbook outcome (to) in gastric cancer surgery at the institution and to assess the impact of achieving to on overall survival (os) and disease-free survival (dfs).Between january 2017 and december 2021, a total of 99 patients were included in this study.The patients underwent either total gastrectomy, subtotal gastrectomy, or trans-hiatal extended gastrectomy for gastric cancer, all with curative intent.Some surgeries were performed open and others laparoscopic.Circular anastomosis was performed utilizing either an echelon circulartm powered stapler (johnson & johnson medical gmbh, ethicon, irvine, ca, usa) or the dst series¿ eea¿ orvil¿ device (medtronic, minneapolis, mn, usa) introduced on the previously made purse-string into the esophagus.Linear anastomosis is performed with a 60 mm linear stapler (echelontm+ stapler, johnson & johnson medical gmbh, ethicon, irvine, ca, usa), and the posterior wall of the esophagus and the anti-mesenteric side of the jejunum are anastomosed side by side with the overlap method.Reported complications included: echelon circulartm powered stapler (ethicon endosurgery); echelontm+ stapler (ethicon endosurgery).Infectious complications (n=?), treatment: not reported.Anastomotic leak (n=?), treatment: not reported.Drainage (n=?), treatment: requiring reinterventions.Ssi (n=?), treatment: not reported.Gi bleeding ,(n=?), treatment: not reported.Pain (n=?), treatment: not reported.In conclusion, to is a quality indicator that is not exclusively limited to reporting morbidity and mortality, but more comprehensively represents a desired postoperative course.We identified minimally invasive surgery as an independent factor positively influencing to.Furthermore, we showed that to significantly influences os and dfs.The implementation of a uniform to metric would allow for more robust quality control between centers.Therefore, future studies into to definition are warranted.
|