ZIMMER BIOMET, INC. COMP LK SCR 3.5HEX 4.75X30 ST; PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER, UNCEMENTED
|
Back to Search Results |
|
| Catalog Number |
180553 |
| Medical Device Problem Code |
Insufficient Device Problem Information (3190)
|
| Health Effect - Clinical Code |
Insufficient Information (4580)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
This event is recorded by zimmer biomet under (b)(4).G2, country event occurred in: australia.D10 narrative: item:ep-010000589, lot: 675430, item number: comp rvrs 25mm bsplt ha+adptr.Item:ep-115395, lot: 093300, item number: e1 44-36 rtnv +3 hmrl brg.Item:115310, lot: 045290, item number: comp rvrs shldr glnsp std 36mm.Item:115370, lot: 795950, item number: comp rvs tray co 44mm.Item:113629, lot: 491120, item number: comp primary stem, 9mm mini.Item: 115397, lot: 478340, item number: comp rvs cntrl 6.5x35mm st/rst.Item: 180553, lot: 420680, item number: comp lk scr 3.5hex, 4.75x30 st.Item:180554, lot: 330090, item number: comp lk scr 3.5hex 4.75x35 st.Item:180554, lot: 146450, item number: comp lk scr 3.5hex 4.75x35 st.The product is in the process of being evaluated by zimmer biomet.Once the product investigation has been completed, a follow up/final report will be submitted.
|
| |
|
Event or Problem Description
|
|
It was reported that a patient had an initial right reverse total shoulder arthroplasty performed, which was revised 4 days later due to dissociation.Subsequently, the patient is now being considered for a patient matched implant due to unknown reasons.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).This follow-up report is being submitted to relay additional information.If any further information is found that would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information is available at the time of this report.
|
| |
|
Event or Problem Description
|
|
No further event information is available at the time of this report.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional information.The following sections were updated: b4, b5, g3, g6, h2, h3, h6, h11.H10: related report #s: 0001825034-2025-00722, 0001825034-2025-00724, 0001825034-2025-00723, 0001825034-2025-00726, 0001825034-2025-00727, 0001825034-2025-00725, 0001825034-2025-00728, 0001825034-2025-00729, 0001825034-2025-00731, 0001825034-2025-00995.No product was returned or pictures provided; visual and dimensional evaluations could not be performed.Review of the device history record(s) identified no deviations or anomalies during manufacturing related to the reported event.Nursing timeline reviewed information provided and identified the following: pmi request received, pending revision due to unknown reason.The rep response states that the patient was booked for a revision approximately 2 years ago (unknown if this is referring to knee or shoulder prosthesis).Medical records were not provided.A definitive root cause cannot be determined.Both baseplates/taper adapters are a part of a bet recall.The reason for this revision is unknown, and therefore, cannot be determined if the reported event is related to the deviations/recall.The reported event is not confirmed.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|