Catalog Number 382944
Medical Device Problem Code Retraction Problem (1536)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/12/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
H.3.A follow up mdr will be submitted if additional information, a device evaluation, or a device history review is completed.
 
Event or Problem Description
It was reported that bd iag bc pro global wing needle was slow to retract.The following information was provided by the initial reporter, translated from french to english: description of the facts, circumstances and means used: the auto-guard device does not work or retracts very slowly.Measures taken: 1 yes.Frequency: 5 very probable (more than once a week).Description of the consequences: risk of needle stick and splashing.
 
Event or Problem Description
No additional information.
 
Additional Manufacturer Narrative
Investigation results: no photos or physical samples that display the reported condition were available for investigation.A device history record review was completed by our quality engineer team for provided material number 382944 and lot number 4298108.The review did not reveal any detected abnormalities during the production process that could have contributed to this defect and all quality tests were found to be within specification.Based on the available information, an exact cause for this incident could not be identified.
 
Additional Manufacturer Narrative
Additional information of fa#.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD IAG BC PRO GLOBAL WING
Common Device Name
PERIPHERAL IV CATHETERS
Manufacturer (Section D)
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
9450 south state street
sandy UT 84070
Manufacturer (Section G)
BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
9450 south state street
sandy UT 84070
Manufacturer Contact
helen cox (mdr)
75 north fairway drive
vernon hills, IL 60061
8473935694
MDR Report Key21640867
Report Number1710034-2025-00426
Device Sequence Number8425519
Product Code FOZ
UDI-Device Identifier00382903829446
UDI-Public(01)00382903829446(11)241105(17)270930(10)4298108
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
UNK
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Remedial Action Recall
Type of Report Initial,Followup,Followup
Report Date (Section B) 06/16/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number382944
Device Lot Number4298108
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/27/2025
Supplement Date Received by Manufacturer04/04/2025
06/13/2025
Initial Report FDA Received Date03/19/2025
Supplement Report FDA Received Date04/04/2025
06/17/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured11/05/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
MDS-25-5274
Patient Sequence Number1