COVIDIEN LP LIGASURE XP; ELECTROSURGICAL, CUTTING COAGULATION ACCESSORIES Back to Search Results
Model Number LXMJ44S
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/07/2025
Type of Reportable Event Malfunction
Event or Problem Description
Patient has failed conservative efforts to lose weight.Patient was brought to the operating suite in stable condition, was positioned supine with pneumatic compression sleeves placed to the legs.Patient also received general anesthesia and was intubated.Abdomen was prepped and draped in sterile fashion.Timeout was performed.When it was time to use the ligasure sealer/ divider, the surgeon noted that there was not enough energy to make the device function well (device was "weak", per surgeon.) the med field representative was contacted whether they could increase the strength, but the answer was no.So, the device was changed to a similar one and the procedure was completed without any further incident.No patient harm.Manufacturer response for electrosurgical, cutting coagulation accessories, ligasure xp (per site reporter).Field representative [redacted] was contacted and will retrieve the device as soon as possible.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LIGASURE XP
Common Device Name
ELECTROSURGICAL, CUTTING COAGULATION ACCESSORIES
Manufacturer (Section D)
COVIDIEN LP
15 hampshire street
mansfield MA 02048
MDR Report Key21641780
Report Number21641780
Device Sequence Number7756059
Product Code GEI
UDI-Device Identifier10884521830967
UDI-Public(01)10884521830967(17)300107(10)50080271X(20)01
Combination Product (Y/N)N
Initial Reporter StateCA
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 03/07/2025
Report Date (Section F) 03/07/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberLXMJ44S
Device Catalogue NumberLXMJ445
Device Lot Number50080271X
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Device Age2 MO
Event Location Hospital
Date Report to Manufacturer03/19/2025
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date03/19/2025
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient Age46 YR
Patient SexFemale
Patient Weight143 KG
Date Report Sent to FDA03/07/2025
-
-