Catalog Number CXA360005
Medical Device Problem Code No Apparent Adverse Event (3189)
Health Effect - Clinical Code Stroke/CVA (1770)
Date of Event 02/13/2025
Type of Reportable Event Serious Injury
Event or Problem Description
The following was reported to gore on (b)(6) 2025 from the imedidata study database: on (b)(6) 2025, this 85-year-old male patient underwent endovascular treatment as a reintervention procedure for an endoleak type ii of a prior endovascular procedure for an abdominal aortic and iliac aneurysm.The patient was treated with an unknown gore® excluder® endoprosthesis by cut-down and conduit.The gore® devices were successfully navigated to the intended location and successfully deployed.The sites were accessed percutaneously.Device catheters were successfully removed after successful access, delivery and deployment of the devices.There was an additional procedure of unknown type.There was no type i or type ii endoleaks observed at the conclusion of the procedure.On (b)(6) 2025, it was noted the patient had a ¿mild stroke¿ related to the procedure.No intervention was necessary.
 
Additional Manufacturer Narrative
H.6.Investigation findings code c20: the device remains implanted and is not available for analysis.H.6.Investigation findings code c19: a review of the manufacturing records for the device verified that the lot met all pre-release specifications.H.6.Investigation conclusions code d12: it should be noted that, per the gore® excluder® conformable aaa endoprosthesis instructions for use, complications associated with the use of the gore® excluder® conformable aaa endoprosthesis that may occur and/or require intervention include, but are not limited to, stroke.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may have not been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® EXCLUDER® CONFORMABLE AAA ENDOPROSTHESIS
Common Device Name
SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL PHOENIX 2 B/P
32470 n. north valley parkway
phoenix AZ 85085
Manufacturer Contact
bryce wargin
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key21658126
Report Number3007284313-2025-03840
Device Sequence Number12996814
Product Code MIH
UDI-Device Identifier00733132650972
UDI-Public(01)00733132650972(17)271002
Combination Product (Y/N)N
Initial Reporter StateUT
Initial Reporter CountryUS
PMA/510(K) Number
P200030
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2025
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Study
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/20/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Catalogue NumberCXA360005
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/26/2025
Initial Report FDA Received Date03/20/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured10/03/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient Age86 YR
Patient SexMale
Patient Weight82 KG
-
-