Catalog Number APOGEE 2300
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Laceration(s) (1946)
Date of Event 02/24/2025
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Procept biorobotics is an importer of the apogee 2300 digital color doppler ultrasound imaging system.The system is a purchased device hence manufacture date is not available.The receiving inspection record for the apogee 2300 digital color doppler ultrasound imaging system serial number (b)(6) was reviewed.It passed the receiving inspection.No reworks were performed by procept biorobotics that were related to the reported event.The review indicated that the device met specifications when released for distribution.The review of the operation manual for the apogee 2300 device (ifu) found that it has covered the related safety instruction: 1.6 safety l) when performing the rectal ultrasound exam, be gentle in the movement.Do not perform violent operation, otherwise it may cause risks of perforation of the rectal wall, damage to the anus and perianal tissues, damage to the rectal mucosa or bleeding.In summary, the root cause for the reported event could not be determined.It was reported that no intervention was taken to address the issue.The user manual of the apogee 2300 device lists damage to the rectal mucosa as a potential risk of the procedure.Based on the review of treatment log files, dhr, and ifu, the event is considered not to be device related.
 
Event or Problem Description
A male patient underwent aquablation therapy for symptomatic benign prostatic hyperplasia (bph).Procept biorobotics corporation (procept) became aware of a rectal mucosal tear with the apogee 2300 digital color doppler ultrasound imaging system and its associated ecbp-1 trus probe after aquablation therapy had been completed.Blood was noted on the probe when the treating surgeon removed the ecbp-1 trus probe.The treating surgeon proceeded to perform a digital rectal exam and observed blood on his glove.A colorectal surgeon was brought in and identified a mucosal tear in the rectum.The mucosal tear was sutured.The patient was discharged home the next day.The treating surgeon reported that no resistance was met when the ecbp-1 trus probe was inserted in the patient and did not mention that there was anything unusual with the patient's anatomy.No malfunction of the apogee 2300 digital color doppler ultrasound imaging system and associated component ecbp-1 trus probe were reported during this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
APOGEE 2300 DIGITAL COLOR DOPPLER ULTRASOUND IMAGING SYSTEM
Common Device Name
ULTRASONIC PULSED DOPPLER IMAGING SYSTEM
Manufacturer (Section D)
SHANTOU INSTITUTE OF ULTRASONIC INSTRUMENT CO. LT
77 jinsha road
shantou, guangdong 51504 1
CN  515041
MDR Report Key21659829
Report Number3012977056-2025-00067
Device Sequence Number8225641
Product Code IYN
UDI-Device Identifier06938396423001
UDI-Public0106938396423001
Combination Product (Y/N)N
Initial Reporter StateNC
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 03/20/2025
Report Date (Section F) 03/20/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberAPOGEE 2300
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date02/27/2025
Event Location Hospital
Date Report to Manufacturer03/20/2025
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date03/20/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device A
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexMale
Date Report Sent to FDA03/20/2025
-
-