| Model Number |
OJR418HM |
| Medical Device Problem Code |
Detachment of Device or Device Component (2907)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
(b)(4).Fisher and paykel healthcare (f&p) are currently in the process of completing our investigation.We will provide a follow up report upon completion of our investigation.
|
| |
|
Event or Problem Description
|
|
A healthcare facility in france reported that two ojr418hm optiflow junior 2 home nasal cannula were found damaged.There was no reported patient involvement.
|
| |
|
Event or Problem Description
|
|
A healthcare facility in france reported that two ojr418hm optiflow junior 2 home nasal cannula were found damaged.There was no reported patient involvement.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).The ojr418 hm optiflow junior 2 nasal cannula was not returned to fisher and paykel (f&p) healthcare for evaluation.Our investigation is based on the photographs provided by the customer and the knowledge of our product.Results: visual inspection of the provided photographs confirmed that the one of the tubing was detached from the cannula.Conclusion: we are unable to determine the cause of the reported event.However, it is most likely caused by the tubing being inadvertently pulled.All optiflow junior cannulas are 100% leak and occlusion tested after final assembly and any cannula that fails is discarded.Samples are also taken and pull tested to check the tube tensile strength and the glue joint strength at the cannula/ tube joint, as well as the swivel grip joint.The subject cannula would have met the required specification at the time of production.The user instructions illustrate in pictorial format the correct set-up and proper use of the optiflow junior 2 nasal cannula.They also state the following: -appropriate patient monitoring (e.G.Oxygen saturation) must be used at all times.Failure to monitor the patient (e.G.In the event of an interruption to gas flow) may result in serious harm or death.-do not wrap, insulate, stretch or crush the tubing as this may impair the performance of this product or compromise safety including potentially causing patient harm).-ensure all connections are secure during use.Check the cannula is undamaged and that the flow path is maintained.Under excessive load, the cannula may disconnect to prevent forces being transferred to the patient.-ensure the patient does not lie on the tubing a this may apply pressure to the patient's ears or face.-failure to apply and use this product within the directions, transport, storage and operating conditions specified in the labelling and user instructions may impair performance of this product or compromise safety (including potentially causing serious patient harm.).
|
| |
|