| Model Number |
C2A12 |
| Medical Device Problem Code |
Installation-Related Problem (2965)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/04/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
No product is being returned for evaluation and no lot number has been provided to applied medical.A follow-up report will be provided upon completion of the investigation.
|
| |
|
Event or Problem Description
|
|
Procedure performed: vaginal hysterectomy.Event description: complaint 1 of 2: (b)(4), lot #unk.Complaint 2 of 2: (b)(4), lot #unk.The surgeon had completed a vaginal hysterectomy for a patient with severe stage 4 prolapse and intended to place the gelpoint v-path post-hysterectomy in order to take the adnexa.She inserted the device manually and did not perform a tissue sweep prior to retracting the outer ring of the alexis 3 times.The surgeon assembled the device, established pneumoperitoneum, and inserted her laparoscopic instrumentation.The surgeon noted that the patient's right tube and ovary were trapped behind the inner ring of the alexis.The surgeon unrolled the outer ring of the alexis and removed the device, then replaced again manually.The surgeon did not perform a tissue sweep prior to retracting the outer ring of the alexis 4 times.Upon entering laparoscopically, the surgeon once again noted entrapment of the patient's right tube and ovary.She attempted to pull externally on the left side of the alexis sheath to free the tissue but was unsuccessful.She unrolled the outer ring of the alexis and removed the device.She replaced it again manually and did not perform a tissue sweep prior to retracting the outer ring of the alexis 1 time.Upon entering laparoscopically, the surgeon noted that the right tube and ovary were once again entrapped.This time, the surgeon had her assist pull on the left side of the alexis sheath and she used her laparoscopic instrumentation to pull the tissue out from behind the inner ring of the alexis.There was no patient injury and the device is unavailable for return.I talked with the aps for this region and asked him how frequently he sees this happen in post-hysterectomy insertions and he told me that he sees it happening a majority of the time in his experience.I am not sure if you'd like to handle this feedback as a complaint since there is a lack of specificity, but i want to make sure that it gets documented somehow.Additional information obtained from [name] (clinical development) on 13mar2025: an epix grasper was used during the case - not affiliated with entrapment.This patient had severe prolapse.This caused the adnexal tissue to have excess laxity.There was no patient injury.Intervention: the surgeon had her assistant pull on the left side of the alexis sheath and she used her laparoscopic instrumentation to pull the tissue out from behind the inner ring of the alexis.Patient status: no patient injury.
|
| |
|
Event or Problem Description
|
|
Procedure performed: vaginal hysterectomy.Event description: complaint 1 of 2: (b)(4), lot #unk.Complaint 2 of 2: (b)(4), lot #unk.The surgeon had completed a vaginal hysterectomy for a patient with severe stage 4 prolapse and intended to place the gelpoint v-path post-hysterectomy in order to take the adnexa.She inserted the device manually and did not perform a tissue sweep prior to retracting the outer ring of the alexis 3 times.The surgeon assembled the device, established pneumoperitoneum, and inserted her laparoscopic instrumentation.The surgeon noted that the patient's right tube and ovary were trapped behind the inner ring of the alexis.The surgeon unrolled the outer ring of the alexis and removed the device, then replaced again manually.The surgeon did not perform a tissue sweep prior to retracting the outer ring of the alexis 4 times.Upon entering laparoscopically, the surgeon once again noted entrapment of the patient's right tube and ovary.She attempted to pull externally on the left side of the alexis sheath to free the tissue, but was unsuccessful.She unrolled the outer ring of the alexis and removed the device.She replaced it again manually and did not perform a tissue sweep prior to retracting the outer ring of the alexis 1 time.Upon entering laparoscopically, the surgeon noted that the right tube and ovary were once again entrapped.This time, the surgeon had her assist pull on the left side of the alexis sheath and she used her laparoscopic instrumentation to pull the tissue out from behind the inner ring of the alexis.There was no patient injury and the device is unavailable for return.I talked with the aps for this region and asked him how frequently he sees this happen in post-hysterectomy insertions and he told me that he sees it happening a majority of the time in his experience.I am not sure if you'd like to handle this feedback as a complaint since there is a lack of specificity, but i want to make sure that it gets documented somehow.Additional information obtained from [name] (clinical development) on 13mar2025: an epix grasper was used during the case - not affiliated with entrapment.This patient had severe prolapse.This caused the adnexal tissue to have excess laxity.There was no patient injury.Intervention: the surgeon had her assistant pull on the left side of the alexis sheath and she used her laparoscopic instrumentation to pull the tissue out from behind the inner ring of the alexis.Patient status: no patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
The event unit was not returned to applied medical for evaluation.However, the customer¿s experience of tissue entrapment was confirmed based on the event description.Based on the description of the event, it is likely that the reported event was caused by user error.The instructions for use (ifu) states, "before retraction of the outer ring, sweep area with fingers to ensure tissue is not trapped between the inner ring and peritoneum." applied medical has performed a historical trend analysis and review of production records and no relevant documentations were identified.
|
| |
|