Model Number SIG30CTAV
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/10/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
D10 concomitant medical products: sig30ctavm, tri 2.0 sig30ctav 30 ct vsclr 12mm, (lot# unknown) sig45ctamt, tri 2.0 sig45ctamt 45 ct med thk 12mm, (lot# unknown) sig60ctamt, tri 2.0 sig60ctamt 60 ct med thk 12mm, (lot# unknown) egia60amt, egia60amt egia 60 artic med thick sulu, (lot# unknown) sig30ctav, tri 2.0 sig30ctav 30 ct vsclr 12mm, (lot# unknown) sig30ctav, tri 2.0 sig30ctav 30 ct vsclr 12mm, (lot# unknown) sig45ctamt, tri 2.0 sig45ctamt 45 ct med thk 12mm, (lot# unknown) sig45ctamt, tri 2.0 sig45ctamt 45 ct med thk 12mm, (lot# unknown) medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Event or Problem Description
According to the reporter, during a pulmonary resection, the shipping wedge broke.There was no patient injury.
 
Event or Problem Description
According to the reporter, during a pulmonary resection, two out of the three small pieces came out in the form of splinters near the protrusion of the yellow tab, and were taken with forceps.There was no patient injury.
 
Additional Manufacturer Narrative
Additional information: b5, g3, h3, h6.H3.Evaluation summary: medtronic conducted an investigation based upon all information received.The device was available for evaluation.Visual inspection noted that the one damaged yellow part and one shipping wedge were received.The reload was fully fired and the interlock was engaged.The jaw of the reload was open.Damage was found on the shipping wedge.Functional testing found that the reload was loaded into a representative handle.The interlock was overridden and the reload was applied to test media.Test media was transected.The reload interlock was tested and found to function properly.It was reported that the shipping wedge broke.The reported issue was confirmed.The product analysis noted evidence that the device was not used as intended.This issue can occur if the shipping wedge pull tab is pulled in a lateral fashion towards the distal end of the sulu channel rather than away from the channel, or if the loading unit is clamped prior to removal of the yellow shipping wedge.The manufacturing records for each device are thoroughly reviewed prior to release to ensure that it meets all medtronic quality specifications.The instructions included with this device provide the following guidance: instructions for proper loading or reload.Clearly states instructions for proper use of stapler.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRI-STAPLE 2.0
Common Device Name
STAPLE, IMPLANTABLE
Manufacturer (Section D)
COVIDIEN LP LLC NORTH HAVEN
195 mcdermott rd
north haven CT 06473
Manufacturer (Section G)
COVIDIEN LP LLC NORTH HAVEN
195 mcdermott rd
north haven CT 06473
Manufacturer Contact
justin ellis
8200 coral sea st ne
mounds view, MN 55112
7635265677
MDR Report Key21728433
Report Number1219930-2025-01490
Device Sequence Number17075858
Product Code GDW
UDI-Device Identifier10884521543737
UDI-Public10884521543737
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K160176
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/03/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberSIG30CTAV
Device Catalogue NumberSIG30CTAV
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/26/2025
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/11/2025
Supplement Date Received by Manufacturer05/17/2025
Initial Report FDA Received Date03/30/2025
Supplement Report FDA Received Date06/03/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-