• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER BIOMET, INC. COMP PRIMARY STEM 10MM MINI; PROSTHESIS, SHOULDER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. COMP PRIMARY STEM 10MM MINI; PROSTHESIS, SHOULDER Back to Search Results
Catalog Number 113630
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Pain (1994)
Date of Event 12/17/2024
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).D10: comp aug mini bsplt w tpr sm cat# 110032410 lot# 64370721, comp rvs cntrl 6.5x20mm st/rst cat# 115394 lot# 599250, comp lk scr 3.5hex 4.75x30 st cat# 180553 lot# 501970, comp lk scr 3.5hex 4.75x15 st cat# 180550 lot# 885030, comp lk scr 3.5hex 4.75x30 st cat# 180553 lot# 050120, comp lk scr 3.5hex 4.75x15 st cat# 180550 lot# 966350, comp rvrs shldr glnsp std 36mm cat# 115310 lot# 930660.H6: mechanical (g04) - stem.The device will not be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch 3500a will be submitted.
 
Event or Problem Description
It was reported from a clinical study that a patient had a right reverse total shoulder arthroplasty performed approximately 5.5 years ago.The patient did very well throughout the study until reporting severe pain and instability with activities at the 5 year follow up.No treatment or intervention has been reported to date.Attempts have been made and additional information on the reported event is unavailable at this time.
 
Additional Manufacturer Narrative
This follow-up report is being submitted to relay additional information.The following sections were updated: b4, b5, e1, e2, e3, g3, g6, h2, h3, h6, h11.No product was returned or pictures provided; visual and dimensional evaluations could not be performed.Review of the device history record(s) identified no deviations or anomalies during manufacturing related to the reported event.Crfs were provided were provided and reviewed by a health care professional.Review of the available records identified the following: [6 weeks post op] x-rays normal.No instability, pain 8.5/10, ases 29.2.Slight pain, no problems.[6 months post op] x-rays normal.No instability, pain 2.1/10, ases 79.5.Slight pain with moderate problems while walking.[2 years post op] x-rays normal.No instability, pain 0/10, ases 85.Moderate pain with slight problems while walking.[3 years post op] x-rays normal.No instability, pain 0/10, ases 81.7.Slight pain, with moderate problems during usual activity and walking.[5 years post op] x-rays normal.Instability 9/10, pain 8.5/10, ases 30.8.Moderate pain and problems while walking, with slight problems washing/dressing and doing usual activities.Ae: pain with activities, no treatment or intervention noted.A definitive root cause cannot be determined.The reported event is not confirmed.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
No further event information is available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COMP PRIMARY STEM 10MM MINI
Common Device Name
PROSTHESIS, SHOULDER
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer (Section G)
ZIMMER BIOMET, INC.
56 e. bell drive
p.o. box 587
warsaw IN 46581
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key21734209
Report Number0001825034-2025-00903
Device Sequence Number8626423
Product Code MBF
UDI-Device Identifier00880304449725
UDI-Public(01)00880304449725(17)280822(10)381700
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K193038
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2019
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Study,Health Professional,User Facility
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/20/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Catalogue Number113630
Device Lot Number381700
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 03/04/2025
Supplement Date Received by Manufacturer08/07/2025
Initial Report FDA Received Date03/31/2025
Supplement Report FDA Received Date08/20/2025
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured08/22/2018
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE H11.
Outcome Attributed to Adverse Event Other;
Patient SexFemale
Patient Weight58 KG
Patient RaceWhite
-
-