MEDOS INTERNATIONAL SÃ RL 5.5HLX ADV PK ANC-DYNA 3-SUT; FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE
|
Back to Search Results |
|
| Catalog Number |
222033 |
| Medical Device Problem Code |
Break (1069)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/19/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Device was used for treatment, not diagnosis.H11: additional narrative: d4, h4: the device manufacture date and expiration date are currently unavailable.Therefore, the udi is incomplete.As of this date, the device has not been returned for evaluation; therefore, the reported condition cannot be confirmed and/or duplicated.
|
| |
|
Event or Problem Description
|
|
It was reported that during a rotator cuff repair procedure, it was discovered that the tip of the 5.5hlx adv pk anc-dyna 3-sut device broke off.According to the reporter, the doctor used a smaller punch to insert the anchor into the hard cortical bone.Due to the nature of the bone, they had to position it at a specific angle, referred to as a dead man's angle.However, when attempting to insert the tip of the 5.5hlx adv pk anc-dyna 3-sut device, the tip broke off.To address this issue, the doctor successfully removed the anchor along with the remaining portion that was still in place.It was not reported if there were any delays to the surgical procedure.It was reported that a spare device was used to complete the surgery.There were no reports of injuries, medical intervention or prolonged hospitalization.All available information has been disclosed.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Device was used for treatment, not diagnosis.H11: additional narrative: correction: d4: the lot number has been found to be invalid and is therefore incorrect.The lot number field should be left blank, and the udi has been updated.Investigation summary = > the complaint device was not returned to j&j medtech orthopaedics, therefore unavailable for a physical evaluation.Given that an invalid lot/serial number was provided, a manufacturing record evaluation (mre) review cannot be performed.If a valid lot/serial number becomes available, the mre review will be performed.Based on the current available information, we cannot determine a root cause for the reported failure.If the complaint device is received in the future, we will reopen the complaint and perform the investigation as appropriate.It has been determined that no corrective and/or preventative action is proposed and there is no indication that a design or manufacturing issue has caused the reported complaint condition.As part of j&j medtech orthopaedics quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.
|
| |
|
Search Alerts/Recalls
|
|
|