EXACTECH, INC. LOGIC TIBIA TRAPTRAY CEM SZ 2.5F/2.5T; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
02-012-41-2525 |
| Medical Device Problem Code |
Loosening of Implant Not Related to Bone-Ingrowth (4002)
|
| Health Effect - Clinical Codes |
Bone Fracture(s) (1870); Necrosis (1971); Synovitis (2094)
|
| Date of Event |
07/25/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
User-related considerations: there were no user-related issues reported that appear to have contributed to the reported event.Patient-related considerations: there are no patient conditions reported that appear to have contributed to the reported event.The reason for the revision reported cannot be confirmed from the information provided but may be the result of femoral loosening, tibial loosening, patellar loosening, and/or suspected prosthesis wear or due to inclusion of the polyethylene in the packaging recall.Potential contributions of user and patient-related considerations to the event could not be assessed as the devices were not available for evaluation and images and radiographs were not provided.D10: it is unclear which insert, tray, or patella is right or left.(b)(6); 02-012-44-2513 - logic tibia implant psc insert, sz 2.5, 13mm.(b)(6); 02-012-44-2511 - logic tibia implant psc insert, sz 2.5, 11mm.(b)(6); 02-012-41-2525 - logic tibia traptray cem sz 2.5f/2.5t.(b)(6); 200-02-32 - three peg patella 32mm.(b)(6); 200-02-32 - three peg patella 32mm.(b)(6); 02-012-41-2525 - logic tibia traptray cem sz 2.5f/2.5t.
|
| |
|
Event or Problem Description
|
|
It was reported via legal documentation that a patient had a left total knee arthroplasty, and then approximately 5 years and 5 months later was revised due to a failed left total knee arthroplasty secondary to aseptic patellar and femoral loosening.The patient was revised to competitors devices.A complete synovectomy was performed.The polyethylene was removed, there was minimal wear.The patella component was grossly loose, and it appeared there was an old patella fracture with large inferior fragment fibrously united.The femoral component was grossly loose, there was moderate bone resorption and necrosis in the medial femoral condyle.The tibial was loosely affixed and removed without difficulty.Sterile dressings were applied, and the patient was awakened and transferred to the recovery room.No complications.There is no other patient demographic or medical history available.There is no device return.There are no photos or other images of the device provided.No additional information is available.
|
| |
|
Search Alerts/Recalls
|
|
|