| Catalog Number |
0166V18S |
| Medical Device Problem Code |
Material Rupture (1546)
|
| Health Effect - Clinical Codes |
Hematuria (2558); Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
|
| Date of Event |
03/17/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.This report references a us equivalent device.The us udi equivalent for this product number is used.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient was admitted to the hospital at 09:30 on (b)(6) 2025 due to difficult urination and urinary pain for 1 day.The diagnosis upon admission was urethral stones, urinary tract infection, and acquired gallbladder loss.At 09:40 on (b)(6) 2025, the patient was given a retained foley catheter, which was yellow in color.At 13:26, the patient found that the foley catheter had slipped out of the body when patient went to the toilet.After reporting to the doctor, the patient was asked whether the patient had removed the catheter by himself.The balloon was checked and found to be ruptured.Patient got bleeding.At 15:34, the patient urinated once, which was light red in color.It is suspected that the spontaneous rupture of the balloon may damage the urethral mucosa and cause hematuria in the patient.No medical intervention was reported.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient was admitted to the hospital at 09:30 on (b)(6) 2025 due to difficult urination and urinary pain for 1 day.The diagnosis upon admission was urethral stones, urinary tract infection, and acquired gallbladder loss.At 09:40 on (b)(6) 2025, the patient was given a retained foley catheter, which was yellow in color.At 13:26, the patient found that the foley catheter had slipped out of the body when patient went to the toilet.After reporting to the doctor, the patient was asked whether the patient had removed the catheter by himself.The balloon was checked and found to be ruptured.Patient got bleeding.At 15:34, the patient urinated once, which was light red in color.It is suspected that the spontaneous rupture of the balloon may damage the urethral mucosa and cause hematuria in the patient.No medical intervention was reported.
|
| |
|
Additional Manufacturer Narrative
|
|
The reported event was inconclusive because no sample was returned.It is unknown whether the device had met relevant specifications.It was unknown whether the product had caused the reported failure.The potential root cause for this failure could be user related (example: contact with sharp object)/ exposure to petrolatum based products/ mechanical failure/operator error).A review of the device history record did not show any problems or condition that would have contributed to the reported issue.The instructions for use were found adequate and state the following: structure & composition: the product include three series: bardex, bardic and bardia.The composition of each series is as follows: bardex, bardic and bardia bi-lumen series are composed of catheter body, inflation cone interface, balloon and valve.Bardia tri-lumen is composed to tube body, inflation cone interface, deflation cone interface, flush cone interface, balloon and valve.The product is with silicone coating.The material of catheter body, inflation conical interface, deflation conical interface, flushing conical interface, balloon is natural latex.The material of valve is polypropylene.Sterilized by radiation.Disposable.Scope of application: foley catheter is intended for use in the drainage of urine from the bladder of children and adults.Precaution: this product contains natural rubber latex which may cause allergic reaction.Sterile unless package has been opened or damage.Warning: do not use petroleum substrate lubricants with the latex- based urethral catheters such as petroleum jelly and label liquid paraffin, which will damage latex and may burst balloon.Water-soluble lubricant can be used.Valve type: use luer slip syringe.Do not use needle.To deflate catheter balloon: gentle insert a syringe in the catheter valve.Never use excessive force to make the syringe stick in the valve.If you notice slow or no deflation, re-seat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen.If permitted by hospital practical, the valve may be cut off.If this fails, please contact an adequately trained professional for assistance, as directed by hospital practical.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient.Storage: catheters need to be stored at room temperature and keep away from the direct light and preferably stored in the original packing box.Do not use the product of have latex allergy.Correction: d.This report references a us equivalent device.The us udi equivalent for this product number is used.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|