BIOMET UK LTD. OXFORD UNI TIB TRAY SZ D RM PMA; PROSTHESIS, KNEE, FEMOROTIBIAL, UNICOMPARTMENTAL
|
Back to Search Results |
|
| Catalog Number |
154725 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Insufficient Information (4580)
|
| Date of Event |
03/25/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that the patient underwent revision surgery of a partial right knee two years and five months post implantation.Attempts have been made and no further information has been provided.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).D-10: 161470, oxf twin-peg cmntd fem lg pma, lot 531280.159582, oxf anat brg rt lg size 3 pma, lot 845720.110035368, biomet bc r 1x40 us, lot ay48al0703.The device will not be returned for analysis; however, an investigation of the reported event is in progress.Once the investigation is completed, a supplemental medwatch 3500a will be submitted.
|
| |
|
Additional Manufacturer Narrative
|
|
This follow-up report is being submitted to relay additional and corrected information.The following sections were updated: b4, b5, g3, g6, h1, h2, h3, h6, h11.The following section was corrected: d4.No product was returned or pictures provided; a product evaluation could not be performed.A review of the device manufacturing records confirmed no abnormalities or deviations that could be related to the reported event.Review of the complaint histories identified additional similar complaints for the reported items and no additional similar complaints for the reported part and lot combinations.Radiographs were provided and reviewed by a radiologist.The review identified two views of the right knee demonstrating a medial compartment hemiarthroplasty without loosening.No acute fracture.Moderate joint effusion.Moderate degenerative changes of the patellofemoral and lateral compartment.Overall fit and alignment of the implant is appropriate.No signs of loosening, wear, radiolucency, or any other contributing factors such as malalignment that would cause issues with any of the components.There are no other anatomical or implant failures that would lead to revision.Further information received from the radiologist does point to a poor fitting femoral component with a gap in between the bone and the hardware and possible bearing wear however this may be artefactual.Based on the available information, the reported event cannot be confirmed.A definitive root cause could not be determined.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
|
| |
|
Event or Problem Description
|
|
No further event information available at the time of this report.
|
| |
|