| Catalog Number |
5833730 |
| Medical Device Problem Codes |
Loss of or Failure to Bond (1068); Restricted Flow rate (1248); Expulsion (2933)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
03/07/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that during hemodialysis, the dialysis catheter had slipped out of place.It was also reported that blood flow become irregular and making it impossible to continue hemodialysis treatment with the catheter.The patient was admitted to the hospital to have the catheter replaced.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
H10: as the lot number for the device was provided, a review of the device history records will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.H11: section a through f ¿ the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
On (b)(6) 2025, a patient underwent the catheter placement procedure.It was reported that during hemodialysis; the dialysis catheter had slipped out of place.It was also reported that blood flow become irregular and making it impossible to continue hemodialysis treatment with the catheter.It was further reported that cuff comes out at the time of dialysis.The patient was admitted to the hospital to have the catheter replaced.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: manufacturing review: the device history records have been reviewed, and this lot met all release criteria.Investigation summary: the physical device was not returned for evaluation.No photos were provided for review.Therefore, the investigation is inconclusive for the reported expulsion, flow issue and cuff failure to bond issue as no objective evidence was provided for review.A definitive root cause could not be determined based upon the provided information.Labelling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.B5, d4 (unique identifier udi), g3, h4, h6 (device, method).Section a through f ¿ the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Search Alerts/Recalls
|