TRIVIDIA HEALTH INC TRUE METRIX; SYSTEM, TEST BLOOD GLUCOSE, OVER THE COUNTER Back to Search Results
Model Number STRIP, TMX CVS 25CTMG/DL
Medical Device Problem Code High Test Results (2457)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/01/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Internal report reference number: (b)(4).Meter and test strips were not returned for evaluation.Retention testing was performed using test strips from the same lot.Retention strip lot tested within specifications.Most likely underlying root cause: mlc-062: user had poor technique.Note: manufacturer contacted customer in several follow-up calls to ensure the replacement products resolved the initial concern - unable to establish contact with customer at this time.
 
Event or Problem Description
Consumer reported complaint for high and erratic blood glucose test results.The customer is concerned with test results from results obtained of 224, 212, 164 and 275 mg/dl.The customer¿s expected am fasting blood glucose test result range is 97-140 mg/dl.The customer feels well and did not report any symptoms.Medical attention is not reported as a result of the actual blood glucose results.During the call, a back to back blood test was not performed by the customer.The product is stored according to specification in the bedroom.The test strip lot manufacturer¿s expiration date is 07/29/2026 and open vial date is a week ago.The meter memory was reviewed for previous test result history: result 1: 224 mg/dl , date : (b)(6), time: 10:21am fasting, result 2: 212 mg/dl, date: (b)(6), time: 8:32am fasting , result 3: 164 mg/dl, date: (b)(6), time: 11:00am fasting , result 4: 123 mg/dl, date: (b)(6), time: 12:00pm fasting , result 5: 275 mg/dl, date: (b)(6), time: 7:30am fasting.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRUE METRIX
Common Device Name
SYSTEM, TEST BLOOD GLUCOSE, OVER THE COUNTER
Manufacturer (Section D)
TRIVIDIA HEALTH INC
2400 nw 55th court
fort lauderdale FL 33309
Manufacturer Contact
juliana arias
2400 nw 55th court
fort lauderdale, FL 33309
MDR Report Key21882975
Report Number1000113657-2025-00141
Device Sequence Number7865374
Product Code NBW
UDI-Device Identifier00021292007829
UDI-Public(01)00021292007829(17)260729(10)ZC5947S
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K140100
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Other
Remedial Action Replace
Type of Report Initial
Report Date (Section B) 04/22/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date07/29/2026
Device Model NumberSTRIP, TMX CVS 25CTMG/DL
Device Lot NumberZC5947S
Was Device Available for Evaluation? No
Distributor Facility Aware Date04/01/2025
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 04/01/2025
Initial Report FDA Received Date04/22/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-