STRYKER ENDOSCOPY-SAN JOSE FG CINCHLOCK SS ANCHOR WITH INSERTER; FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE Back to Search Results
Catalog Number CAT02462
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/25/2025
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that when the handle was depressed, the pull wire did not come out with the inserter and was left sticking out of the middle of the anchor all the way out of the patient.Had to manually pull the wire out of the anchor.Anchor remained implanted.
 
Additional Manufacturer Narrative
Additional information will be provided once the investigation has been completed.
 
Additional Manufacturer Narrative
The device is not available for investigation as it was reported the anchor was implanted and the handle inserter was discarded.This complaint investigation was closed based on the device not received, therefore the reported failure mode was not confirmed.In the event that the device is received, the complaint will be reopened and the investigation will be updated with new results.Alleged failure: pull wire remaining in the anchor probable root cause: application - user unfamiliarity with device the reported failure mode will be monitored for future reoccurrence.
 
Event or Problem Description
It was reported that when the handle was depressed, the pull wire did not come out with the inserter and was left sticking out of the middle of the anchor all the way out of the patient.Had to manually pull the wire out of the anchor.Anchor remained implanted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FG CINCHLOCK SS ANCHOR WITH INSERTER
Common Device Name
FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE
Manufacturer (Section D)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer (Section G)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
Manufacturer Contact
lucas wolski
5900 optical court
san jose, CA 95138
4087542000
MDR Report Key21885737
Report Number0002936485-2025-00365
Device Sequence Number12786680
Product Code MBI
UDI-Device Identifier07613252633228
UDI-Public07613252633228
Combination Product (Y/N)N
Initial Reporter StateTN
Initial Reporter CountryUS
PMA/510(K) Number
K131769
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 08/11/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberCAT02462
Device Lot Number24315AE2
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Follow-Up
Initial Date Received by Manufacturer 03/25/2025
Supplement Date Received by Manufacturer07/13/2025
Initial Report FDA Received Date04/22/2025
Supplement Report FDA Received Date08/11/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured11/10/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-