|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Additional narrative: d4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.H11 additional narrative: h3, h6: the product was returned to j&j medtech orthopaedics for evaluation.Visual inspection of the returned device found signs normal of explanation and implantation process.No signs of manufactured defects or anything that could help to the malfunction of the device.A dimensional inspection was not performed since it was not applicable to the complaint condition.A functional evaluation was performed several attempts of assemble and disassembly were made.It was possible to preformed the complete assembly process, the mating devices used were returned also in this complaint (5560553095t, ti lrdsd rod 5.5 x 95mm and 5560126050f, poly screw, fen, 6mm x 50) and no malfunction in the assemble process were found.Once the assembly process was complete the devices moved strongly to see if the loose condition was present.The assembly work as expected.However, due the photograph evidence provided by the customer, the complaint allegation can be confirmed.Therefore, the potential cause is traced to user due to the information mentioned in the event description and the investigation findings.The overall complaint was confirmed as the observed condition of the set screw t27 would have contributed to the complained device issue.Based on the investigation findings, the potential cause is traced to user, and it has been determined that no corrective and/or preventative action is proposed.There is no indication that a design or manufacturing issue has caused the reported complaint condition.As part of j&j medtech orthopaedics quality process, all devices are manufactured, inspected, and released to approved specifications.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post-market safety surveillance activities.Dece history lot: part# 5560010000.Lot # 417228.Manufacturing site: depuy synthes.Supplier: (b)(4).Release to warehouse date: 18 nov 2024.Expiration date: na.A manufacturing record evaluation was performed for the finished article lot and no non-conformances were identified.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|