|
ALERE SAN DIEGO, INC. MEDLINE HCG URINE CASSETTE; VISUAL, PREGNANCY HCG, PRESCRIPTION USE
|
Back to Search Results |
|
| Model Number |
FHC-102 |
| Medical Device Problem Code |
False Positive Result (1227)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/01/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
B3 - date of event: was selected as 1apr2025 as customer indicated the event took place between 1apr2025-14apr2025.Results pending completion of the investigation.
|
| |
|
Event or Problem Description
|
|
The customer reported their facility received several false positive hcg results using medline hcg urine cassettes on 5 different patients.The customer was unable to provide specifics as to when the false positives occurred, however they indicated the events occurred sometime between 1apr2025 and 14apr2025.Each patient presented for an unspecified reason, and all patients provided a fresh urine sample that was free of visible contaminants.Three to four drops of urine were applied to the corresponding device for each patient.Please note, the package insert states "place the test cassette on a clean and level surface.Hold the pipette vertically and transfer 3 full drops of urine (approx.100ul) to the specimen well (s) of the test cassette, and then start the timer.".The results were read at 3 minutes and a positive hcg result was obtained for each of the five patients.Patients 2-5 were all retested using another device from the same lot number and faint positive hcg results were obtained.Although requested, no further information was provided.The customer indicated no negative impact occurred as a result of the false positive hcg results.This mdr is for patient 3.See mdr 2027969-2025-00115, 2027969-2025-00116, 2027969-2025-00118, 2027969-2025-00119 for patients 1, 2, 4, and 5 respectively.
|
| |
|
Event or Problem Description
|
|
The customer reported their facility received several false positive hcg results using medline hcg urine cassettes on 5 different patients.The customer was unable to provide specifics as to when the false positives occurred, however they indicated the events occurred sometime between 1apr2025 and 14apr2025.Each patient presented for an unspecified reason, and all patients provided a fresh urine sample that was free of visible contaminants.Three to four drops of urine were applied to the corresponding device for each patient.Please note, the package insert states "place the test cassette on a clean and level surface.Hold the pipette vertically and transfer 3 full drops of urine (approx.100ul) to the specimen well (s) of the test cassette, and then start the timer.".The results were read at 3 minutes and a positive hcg result was obtained for each of the five patients.Patients 2-5 were all retested using another device from the same lot number and faint positive hcg results were obtained.Although requested, no further information was provided.The customer indicated no negative impact occurred as a result of the false positive hcg results.This mdr is for patient 3.See mdr 2027969-2025-00115, 2027969-2025-00116, 2027969-2025-00118, 2027969-2025-00119 for patients 1, 2, 4, and 5 respectively.
|
| |
|
Additional Manufacturer Narrative
|
|
B3 - date of event: was selected as 1apr2025 as customer indicated the event took place between 1apr2025-14apr2025.H3, h6 and h11 were updated to include investigation findings.Investigation conclusion: retained and returned devices from the reported lot number were tested with hcg-negative clinical urine samples.The results were read at 3 and 4 minutes and all devices yielded valid negative results.No false positive results were observed during in-house testing.The case details were reviewed along with the complaint history for the reported issue and no indications of a systemic issue were identified.Manufacturing batch record review did not uncover any relevant non-conformances and found that the lot met quality control specifications.Review of the risk management report for this product found that the reported issue is within the risk profile for this device; no new hazard has been identified.A root cause could not be determined from the available information as the reported issue was not replicated during testing of retention and returned product.Complaints are tracked and trended on a monthly basis.Per the package insert: - very low levels of hcg (less than 50 miu/ml) are present in urine specimen shortly after implantation.However, because a significant number of first trimester pregnancies terminate for natural reasons, a test result that is weakly positive should be confirmed by retesting with a first morning urine specimen collected 48 hours later.- a number of conditions other than pregnancy, including trophoblastic disease and certain non-trophoblastic neoplasms including testicular tumors, prostate cancer, breast cancer, and lung cancer, cause elevated levels of hcg.Therefore, the presence of hcg in urine specimen should not be used to diagnose pregnancy unless these conditions have been ruled out.- this test provides a presumptive diagnosis for pregnancy.A confirmed pregnancy diagnosis should only be made by a physician after all clinical and laboratory findings have been evaluated.
|
| |
|
Search Alerts/Recalls
|
|
|