MAUDE Adverse Event Report: ERIKA DE REYNOSA, S.A. DE C.V. LIBERTY CYCLER SET, SINGLE PATIENT CONN; SYSTEM, PERITONEAL, AUTOMATIC DELIVERY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ERIKA DE REYNOSA, S.A. DE C.V. LIBERTY CYCLER SET, SINGLE PATIENT CONN; SYSTEM, PERITONEAL, AUTOMATIC DELIVERY Back to Search Results
Catalog Number 050-87215A
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/29/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Plant investigation: the plant investigation is in process.A supplemental mdr will be submitted upon completion of this activity.
 
Event or Problem Description
A peritoneal dialysis (pd) patient reported the cycler prompted with multiple m31 - air detected in cassette warnings during drain 1 of 4 of treatment.Fluid was seen in the cassette door.The film on the back of the cassette door was loose.The patient was to re-setup the cycler with new supplies and drain in drain 0.Upon follow up, the peritoneal dialysis registered nurse (pdrn) confirmed the reported event.The pdrn stated fluid was noted following the reported m31 air detected in cassette warning cycler alarms and during step 9 of treatment as treatment was cancelled.The patient cancelled treatment and found fluid in the pump module area and on the external of the cassette.The film on the back of the cassette was loose but a hole was not noted.The cause of the fluid leak was unknown.The patient confirmed there were no symptoms, adverse events, or injuries requiring any other medical intervention required as a result of the reported event.The pdrn stated the patient was trained on performing stat drains, as well as manual peritoneal dialysis therapy if needed, and stated the patient contacted the on-call nurse for assistance and completed treatment using the cycler after re-setting up supplies on the night of the reported event.The patient has since resumed treatment using the cycler without further issue.The pdrn stated the cycler set (cassette) used was discarded and was no longer available to be returned for investigation.
 
Additional Manufacturer Narrative
Plant investigation: as the device was not returned to the manufacturer, a physical evaluation could not be performed.A batch records review was conducted by the manufacturer for the reported lot.There were no non-conformances or abnormalities identified during the manufacturing process which could be associated with the reported event.The entire lot has been sold and distributed.In addition, a device history review was performed and confirmed that the results of the in-progress and final quality control (qc) testing met all requirements.The lot met all specifications for release.A product history review did not reveal a probable cause for the customer complaint.As a physical evaluation could not be performed, a definitive conclusion regarding the reported incident could not be reached and a cause could not be confirmed.
 
Event or Problem Description
A peritoneal dialysis (pd) patient reported the cycler prompted with multiple m31 - air detected in cassette warnings during drain 1 of 4 of treatment.Fluid was seen in the cassette door.The film on the back of the cassette door was loose.The patient was to re-setup the cycler with new supplies and drain in drain 0.Upon follow up, the peritoneal dialysis registered nurse (pdrn) confirmed the reported event.The pdrn stated fluid was noted following the reported m31 air detected in cassette warning cycler alarms and during step 9 of treatment as treatment was cancelled.The patient cancelled treatment and found fluid in the pump module area and on the external of the cassette.The film on the back of the cassette was loose but a hole was not noted.The cause of the fluid leak was unknown.The patient confirmed there were no symptoms, adverse events, or injuries requiring any other medical intervention required as a result of the reported event.The pdrn stated the patient was trained on performing stat drains, as well as manual peritoneal dialysis therapy if needed, and stated the patient contacted the on-call nurse for assistance and completed treatment using the cycler after re-setting up supplies on the night of the reported event.The patient has since resumed treatment using the cycler without further issue.The pdrn stated the cycler set (cassette) used was discarded and was no longer available to be returned for investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LIBERTY CYCLER SET, SINGLE PATIENT CONN
Common Device Name
SYSTEM, PERITONEAL, AUTOMATIC DELIVERY
Manufacturer (Section D)
ERIKA DE REYNOSA, S.A. DE C.V.
mike allen #1331
parque industrial reynosa
reynosa 88780
MX  88780
Manufacturer (Section G)
ERIKA DE REYNOSA, S.A. DE C.V.
director, quality systems
900 w zaragosa drive suite d
pharr TX 78577
Manufacturer Contact
jessica trujillo
920 winter st
waltham, MA 02451
6174175172
MDR Report Key21944783
Report Number0008030665-2025-01000
Device Sequence Number8534880
Product Code FKX
UDI-Device Identifier00840861102709
UDI-Public00840861102709
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K173718
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Consumer,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 06/16/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Catalogue Number050-87215A
Device Lot Number24JR08076
Was Device Available for Evaluation? No
Device AgeMO
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/29/2025
Supplement Date Received by Manufacturer06/16/2025
Initial Report FDA Received Date05/01/2025
Supplement Report FDA Received Date06/16/2025
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured07/31/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
LIBERTY SELECT CYCLER; LIBERTY SELECT CYCLER; PD SOLUTION; PD SOLUTION
Patient Age66 YR
Patient SexMale
Patient Weight55 KG
-
-