Quick Links: Skip to main page content
Skip to Search
Skip to Topics Menu
Skip to Common Links
U.S. Food & Drug Administration
Follow FDA
En Español
Search FDA
Home
Food
Drugs
Medical Devices
Radiation-Emitting Products
Vaccines, Blood & Biologics
Animal & Veterinary
Cosmetics
Tobacco Products
MAUDE Adverse Event Report: BIOHORIZONS INC. BIOHORIZONS INC.; DENTAL IMPLANT
FDA Home
Medical Devices
Databases
-
510(k)
|
DeNovo
|
Registration & Listing
|
Adverse Events
|
Recalls
|
PMA
|
HDE
|
Classification
|
Standards
CFR Title 21
|
Radiation-Emitting Products
|
X-Ray Assembler
|
Medsun Reports
|
CLIA
|
TPLC
BIOHORIZONS INC. BIOHORIZONS INC.; DENTAL IMPLANT
Back to Search Results
Model Number
IL-3312
Medical Device Problem Code
Failure to Osseointegrate (1863)
Health Effect - Clinical Code
Insufficient Information (4580)
Date of Event
04/10/2025
Type of Reportable Event
Serious Injury
Event or Problem Description
Implant failed to osseointegrate.
Event or Problem Description
Implant failed to osseointegrate.
Search Alerts/Recalls
New Search
|
Submit an Adverse Event Report
Brand Name
BIOHORIZONS INC.
Common Device Name
DENTAL IMPLANT
Manufacturer
(Section D)
BIOHORIZONS INC.
2300 riverchase center
birmingham AL 35244
Manufacturer
(Section G)
BIOHORIZONS INC.
2300 riverchase center
birmingham AL 35244
Manufacturer Contact
anissa smith
2300 riverchase center
birmingham, AL 35244
MDR Report Key
21984117
Report Number
1060818-2025-25626
Device Sequence Number
20970718
Product Code
DZE
UDI-Device Identifier
00847236016067
UDI-Public
00847236016067
Combination Product (Y/N)
N
Initial Reporter Country
TW
PMA/510(K) Number
K223697
Number of Events Summarized
1
Summary Report (Y/N)
N
Device Implanted Year
2025
Device Explanted Year
2025
Serviced by Third Party (Y/N)
N
Reporter Type
Manufacturer
Report Source
Company Representative
Initial Reporter Occupation
Dentist
Type of Report
Initial,Followup
Report Date
(Section B)
06/08/2025
1
Device was Involved in the Event
1
Patient was Involved in the Event
Is this an Adverse Event Report?
Yes
Is this a Product Problem Report?
No
Operator of Device
Health Professional
Device Model Number
IL-3312
Device Catalogue Number
IL-3312
Device Lot Number
2200398
Was Device Available for Evaluation?
Yes
Is the Reporter a Health Professional?
Yes
Type of Report(Section G)
Thirty-Day
Initial Date Received by Manufacturer
04/10/2025
Supplement Date Received by Manufacturer
05/16/2025
Initial Report FDA Received Date
05/08/2025
Supplement Report FDA Received Date
06/16/2025
Was Device Evaluated by Manufacturer? (Y/N)
Yes
Date Device Manufactured
01/17/2022
Is the Device Labeled for Single Use? (Y/N)
Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device
Initial
Patient Sequence Number
1
Outcome Attributed to Adverse Event
Required Intervention;
Patient Sex
Unknown
-
-