Product complaint # (b)(4).H6 component code: g07002 - pending evaluation of returned device.The device upon which this medwatch is based has been received, however, the evaluation is not yet complete.Any further information derived from the evaluation will be submitted in a supplemental 3500a form.This report is being submitted pursuant to the provisions of 21 cfr part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
|
It was reported by a sales rep that, during an unknown respiratory surgery, in a urologic case, the needle was broken at the swage part.In a da vinci case, the needle tip did not fall off.No piece fell into the patient.It was not a control release needle.Another product was used to complete the case.When we send the sample to you, we will let you know its return date and tracking number.There were no adverse consequences to the patient.Further details are not provided from the hp.Affiliate reference number: (b)(4).
|
|
Product complaint # (b)(4) this report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information: h6, d9, h3, h4, d4 h3 investigation summary: the product was returned to ethicon for evaluation.One empty foil packet, one needle and a suture were received for analysis.Product code z464h.Upon visual inspection of the sample, it was observed the needle was broken at the swage area and a part of the needle was noted to be attached to the suture.The sample will be shipped to hsa for further analysis due to the needle breakage.Also, marks that appear to be by use of the surgical instrument were observed near the damage.As part of our quality process, the manufacturing records of this lot-serial number were reviewed, and the manufacturing standards were met prior to the release of this batch.No conclusion could be reached due to the sample needs additional evaluation by hsa.As part of the ethicon quality process, all devices are manufactured, inspected, and released to approved specifications.Needle analysis: a failed suture needle, labeled as (b)(4), was submitted for fractographic evaluation on may 28, 2025.The component was identified as product code z464h.It was requested that hsa assess the fracture mode of the failure.According to the information, it was reported breakage needle.The product received for analysis was z464h.Visual inspection and metallurgical analysis were performed on the returned product.A fracture was observed at the suture attachment of the needle.The needle was received in two pieces, only one of the mating fracture surfaces was examined for this evaluation.A scanning electron microscope (sem) was used to examine the fracture surfaces and surrounding area of the needle.The fracture surfaces were examined in multiple locations to determine the fracture mode.The evaluation of (b)(4) revealed the fracture was composed of microvoid coalescence, which is evidence of a ductile fracture mode.Mechanical damage observed coincidental to the fracture provides additional evidence that the failure was induced by mechanical deformation leading to ductile overload.This was a ductile fracture.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.
|