H6: a review of the manufacturing records for the device verified that the lot met all pre-release specifications.H6: code d12: according to the the gore® dryseal flex introducer sheath instructions for use, adverse events that may occur and / or require intervention or additional intraoperative procedure time include, but are not limited to: vascular trauma (i.E., dissection, rupture, perforation, tear, etc).W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
|
The following information was reported to gore: on (b)(6) 2024, this patient underwent an ascending aortic arch replacement using the elephant trunk technique.On (b)(6) 2024, this patient underwent endovascular treatment for a thoracic aortic aneurysm using gore® tag® conformable thoracic stent grafts with active control system, and gore® dryseal flex introducer sheath as an accessory.Two ctags were deployed just below the branch of the artificial blood vessel.On an unknown date, a follow-up ct scan revealed a type i endoleak on the lesser curvature side of the distal ctag.Additionally, the distal ctag was suspected to have migrated towards the proximal side.On (b)(6) 2025, a reintervention was performed.An additional stent graft was implanted as a treatment for the endoleak (this event will be captured in (b)(4)).A dissection of the right external iliac artery was observed on the preoperative ct scan.It was considered to have occurred during the procedure on (b)(6) 2024, but no specific treatment was performed.It has not been identified which device caused the dissection.The patient tolerated the procedure.
|