| Catalog Number |
47512015M |
| Medical Device Problem Code |
Burst Container or Vessel (1074)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/22/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
As reported, the balloon of a 150cm saberx014 percutaneous transluminal angioplasty (pta) balloon catheter ruptured and was removed.A non-cordis device was used as replacement to complete the procedure.There was no reported patient injury.The device was inflated to 6 atmospheres (atm) before the anomaly was noted, and the gauge of the indeflator indicated a loss of pressure about 3 seconds after pressure was maintained.The lesion was the superficial femoral artery and femoral popliteal which had severe calcification and occlusion.A contralateral approach was made.After an unknown guidewire crossed, an intravascular ultrasound (ivus) could not cross and the complaint device was used; it crossed and inflated; however, ruptured.The intended procedure was an endovascular thrombectomy (evt).The product was stored and handled according to the instructions for use (ifu).No device damage was noticed prior to opening the package.There was no difficulty removing the device from the sterile packaging or the protective balloon cover, and no difficulty removing any of the sterile packaging components.A contralateral approach was used.The target site vessel characteristics included severe calcification and 100% stenosis, with no acute angle or bifurcation.The vessel characteristics accessing the target site showed no calcification, tortuosity, stenosis, acute angle, or bifurcation.The device maintained negative pressure during preparation and was not put into an acute bend at any point during the procedure.The device did not kink at any time during the procedure, and no anomalies were noted after the device was delivered to the lesion.The device was able to be removed easily from the patient and was removed intact in one piece.The contrast to saline ratio was 1:2.The same indeflator was used successfully with other devices.No anomalies were noted while inflating the device with positive pressure, and there was no anomaly that prevented the device from inflating.No resistance was met while withdrawing the device from the vessel, into the guide catheter, or through the sheath or introducer guide.The product was not returned for analysis.A review of the manufacturing documentation associated with lot 2306278337 presented no issues during the manufacturing process that can be related to the reported event.The reported event of ¿balloon burst at/below rbp¿ could not be evaluated since the device was not returned for evaluation.With the limited information provided, without the return of the device, and with no procedural films, the cause of the reported event could not be determined.It is possible that factors related to the procedure, handling, and/or patient anatomy contributed to the reported event.The reported severe calcification and complete occlusion of the artery may have contributed to the reported event; it is likely to have caused damage to the balloon material that led to its rupture.According to the warnings in the safety information in the instructions for use, ¿prior to angioplasty, the catheter should be examined to verify functionality and integrity, and ensure that its size and shape are suitable for the specific procedure for which it is to be used.Do not use if product damage is suspected or evident.To reduce the potential for vessel damage or the risk of dislodgement of particles it is very important that the inflated diameter of the balloon should approximate the diameter of the vessel just proximal and distal to the lesion.The balloon dimensions are printed on the product label.The compliance table incorporated with the product shows how balloon diameter increases as pressure increases.Do not exceed the rated burst pressure recommended on the label.The rated burst pressure is based on the results of in vitro testing.At least 99.9% of the balloons (with a 95% confidence) will not burst at or below their rated burst pressure.Use of a pressure monitoring device is recommended to prevent over-pressurization.Pressure in excess of the rated burst pressure can cause balloon rupture and potential inability to withdraw the catheter through the introducer sheath.Balloon rupture can cause vessel damage and the need for additional intervention.Use only the recommended balloon inflation medium (a 50/50 mixture by volume of contrast medium and normal saline).Never use air or any gaseous medium to inflate the balloon.¿ based on the information available for review, there is no indication to suggest that the reported failure could be related to the design or manufacturing process of the unit.Therefore, no corrective/preventative actions will be taken at this time.
|
| |
|
Event or Problem Description
|
|
As reported, the balloon of a 150cm saberx014 percutaneous transluminal angioplasty (pta) balloon catheter ruptured and was removed.A non-cordis device was used as replacement to complete the procedure.There was no reported patient injury.The device was inflated to 6 atmospheres (atm) before the anomaly was noted, and the gauge of the indeflator indicated a loss of pressure about 3 seconds after pressure was maintained.The lesion was the superficial femoral artery and femoral popliteal which had severe calcification and occlusion.A contralateral approach was made.After an unknown guidewire crossed, an intravascular ultrasound (ivus) could not cross and the complaint device was used; it crossed and inflated; however, ruptured.The intended procedure was an endovascular thrombectomy (evt).The product was stored and handled according to the instructions for use (ifu).No device damage was noticed prior to opening the package.There was no difficulty removing the device from the sterile packaging or the protective balloon cover, and no difficulty removing any of the sterile packaging components.A contralateral approach was used.The target site vessel characteristics included severe calcification and 100% stenosis, with no acute angle or bifurcation.The vessel characteristics accessing the target site showed no calcification, tortuosity, stenosis, acute angle, or bifurcation.The device maintained negative pressure during preparation and was not put into an acute bend at any point during the procedure.The device did not kink at any time during the procedure, and no anomalies were noted after the device was delivered to the lesion.The device was able to be removed easily from the patient and was removed intact in one piece.The contrast to saline ratio was 1:2.The same indeflator was used successfully with other devices.No anomalies were noted while inflating the device with positive pressure, and there was no anomaly that prevented the device from inflating.No resistance was met while withdrawing the device from the vessel, into the guide catheter, or through the sheath or introducer guide.The device was discarded and will not be returned.
|
| |
|
Additional Manufacturer Narrative
|
|
Additional information is pending and will be submitted within 30 days upon receipt.
|
| |
|
Search Alerts/Recalls
|
|
|