ANGIODYNAMICS, INC SMART PORT CT; PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR
|
Back to Search Results |
|
| Model Number |
H787CT66PTPD0 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Dyspnea (1816); Embolism/Embolus (4438); Thrombosis/Thrombus (4440); Bacteremia (4846)
|
| Date of Event |
05/14/2022
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
The customer's reported complaint description of patient infection cannot be confirmed given the patient centric nature of this serious adverse event (sae).No port device was returned for evaluation since there was no report of port device malfunction, damage or performance issue during use.A device history record (dhr) review of the indicated packaging lot revealed no quality related issues or manufacturing deficiencies at the time of manufacture.Sterilization load release records were reviewed for the packaging lot in question; no issues were observed.The port was implanted into the patient 5 months prior to the patient's infection.There was no report of port device malfunction or performance issue during use.If the manufacturing/packaging/sterilization of the port device in question was to contribute to an infection in the patient it would have likely occurred shortly after the implant date and not 5 months later.Device directions for use cautions that each access of the port should be performed using aseptic technique, following the institutions universal precautions.There is no indication from the reported complaint that the manufacturing/packaging/sterilization of the port device could have contributed to the patient's infection.Infection is cautioned in the device dfu as a potential complication of port system use.Labeling review: the directions for use (dfu) that is provided in the smartport device contains the following directions and precautions: contraindications: · catheter insertion in the subclavian vein medial to the border of the first rib, an area which is associated with higher rates for pinch-off.Warnings: · the device is to be implanted, used, maintained, and removed in strict accordance with institutional and or centers for disease control (cdc) guidelines or policies.· reuse of single-use devices creates a potential risk of patient or user infections.Contamination of the device may lead to injury, illness or death of the patient.· do not use syringes smaller than 10 ml syringe when accessing the port as system damage can occur.Flushing occluded catheters with small syringes can create excessive pressures within the port system.Absence of a blood return or a poor blood return can be a sign of a potential complication such as occlusion, kinking, breakage, pinch-off syndrome, fibrin formation, thrombosis or malposition.This should be evaluated prior to device usage.· a blood return should be present prior to usage of device for any therapy or testing.· do not attempt to measure the patient's blood pressure on the arm in which a peripheral system is located, since catheter occlusion or other damage to the catheter could occur.· if the patient complains of pain, or there is swelling when the device is flushed or when medication or contrast media is administered, evaluate the device for infiltration, proper needle placement, and potential complications such as occlusion, kinking, breakage, pinch-off syndrome, thrombosis or malposition.Failure to assess these complaints or observations can lead to device failure.Precautions: · carefully read and follow all instructions prior to use.· strict aseptic technique is of paramount importance when implanting any device.Potential complications: use of an angiodynamics port system involves potential risks normally associated with the insertion or use of any implanted device or indwelling catheter including but not limited to: erosion of vessel and skin, implant rejection, infection, necrosis of scarring of skin over implant area, vessel trauma post-operative care: the incision site should be monitored for signs of infection, inflammation, hematoma, device rotation or erosion.Routine wound care should be given to these sites.The smart port ct implantable port may be used immediately after verification of catheter placement.Instruct patient to avoid any heavy exertion or strenuous activity during the first few days after surgery.General guidelines: · each access of an angiodynamics smart port ct implantable port should be performed using aseptic technique.· follow institutional universal precautions.A review of the angiodynamics complaint system noted no adverse trends for this complaint type and product family.This type of complaint continues to be monitored for trends.Reference (b)(4).
|
| |
|
Event or Problem Description
|
|
On or about (b)(6) 2021, plaintiff underwent placement of the following angiodynamics' smartport ct product: model/cat number: h787ct66ptpd0, lot number: 5692897, for the purposes of plaintiff's chemotherapy.Upon information and belief, the aforementioned device's description is as follows: smart port ct peripheral/chest titanium port system with attachable 6.6f x 55cm polyurethane catheter and 7f introducer kit.On or about (b)(6) 2021, the device at issue was implanted by dr.(b)(6), at (b)(6), for the purposes indicated above.Upon information and belief, on (b)(6) 2022, plaintiff presented to (b)(6) hospital, where plaintiff was then diagnosed with bacteremia and shortness of breath.Upon information and belief, on or about (b)(6) 2022, plaintiff was also diagnosed with acute embolism and thrombosis of superficial veins of right upper extremity.On or about (b)(6) 2022, plaintiff's bacteremia was noted to be mrsa bacteremia by (b)(6), md, attending physician, (b)(6) medical center.Dr.(b)(6) noted that plaintiff's mrsa bacteremia's likely source was plaintiff's port.On or about (b)(6) 2022, plaintiff's blood, bacteriology culture's 1st set's results showed the growth of staphylococcus aureus; the gram stain showed gram positive cocci.On or about (b)(6) 2022, plaintiff's blood, bacteriology culture, 2nd set showed gram positive cocci.Plaintiff's blood and bacteriology culture collected around that time also showed the growth of mrsa (methicillin-resistant staphylococcus aureus); gram stain, both aerobic and anaerobic, showed gram positive cocci.Upon information and belief, plaintiff was admitted to the (b)(6) hospital, between (b)(6) 2022, and (b)(6) 2022, with msra port infection.On or about (b)(6) 2022, plaintiff's port-a-cath at issue was removed due to the by dr.(b)(6).
|
| |
|
Search Alerts/Recalls
|
|
|