| Catalog Number |
07.02053.001 |
| Medical Device Problem Code |
Calibration Problem (2890)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
04/01/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that intra-operatively, two torque limiting handles did not provide adequate torque, allowing for rod movement during compression.Another torque handle was used to complete the procedure with no patient impact.This is report one of two for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrections in d4: lot & udi numbers, d9, and h3.Additional information in h4.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.Reference report 3012447612-2025-00220.
|
| |
|
Additional Manufacturer Narrative
|
|
D4: the remainder of the udi number is unknown because the lot number is not available.Without a product return, no product evaluation is able to be conducted.The lot number is unknown; therefore the device history records are unable to be reviewed.Current information is insufficient to permit a valid conclusion about the cause of this event.If additional information is obtained that adds value to the relevant content of this report and/or a conclusion can be drawn, a follow-up report will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that intra-operatively, two torque limiting handles did not provide adequate torque, allowing for rod movement during compression.Another torque handle was used to complete the procedure with no patient impact.This is report one of two for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
H3: "device evaluation anticipated, but not yet begun" is erroneous and no longer applies.The device was evaluated.Corrections in h3.Additional information in h6: investigation type, findings, and conclusions.Device evaluation: the returned device matches the information in the complaint file and was examined.Visual inspection revealed no signs of damage.The torque output was tested with load cell id: (b)(4).The torque output of the handle ranged from 91.2 in-lbs to 93.0 in-lbs.Per drawing (b)(4) rev.D, the torque output should be 90 in-lbs +/- 5% (85.5 in-lbs to 94.5 in-lbs).Root cause: a definitive root cause cannot be determined as the returned device was found to function as expected.Dhr review: the dhr was reviewed.There are no indications of manufacturing issues which would have contributed to this event and the device was likely conforming when it left highridge medical¿s control.Device usage: this device is used for treatment.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that intra-operatively, two torque limiting handles did not provide adequate torque, allowing for rod movement during compression.Another torque handle was used to complete the procedure with no patient impact.This is report one of two for this event.
|
| |
|