|
Supplemental report 01:(b)(4).Additional information - this mdr is being submitted to include the below: h6: investigation results under type of investigation, investigation findings, investigation conclusions h11: investigation summary the information in this complaint (b)(4) has been evaluated.The batch 6007389 in question was manufactured at the reynosa site.Investigation process of the complaint was carried out in accordance with work instruction (wi) guidance for visual testing for complaints area version 3 and wi guidance for functional testing for complaints area version 2 for the code leakage from connection between the tubing connector and the infusion set (cannula part/base piece).Complaint investigations.Photo/sample was not provided.In order to test the product, the reference samples from the lot have been requested.Test results: visual test according to wi version 3 on reference samples, 10 samples out 10 samples passed the test.Functional air flow test 1 according to wi version 2 on reference samples, 10 samples out 10 samples passed the test.Functional air leak test 2 according to wi version 2 on reference samples, 10 samples out 10 samples passed the test.Device history record (dhr) review: the lot 6007389 was manufactured according to the wi version 114 manufactured in the line l-10, li103, on 29/may/2023, with a total of 29,400 units.Review of the dhr showed that all relevant tests required during the related processes had been fulfilled and met the requirements.No deviation were identified; no maintenance events were recorded.Trending: a query was run in database on 19/jun/2025 against malfunction code leakage from connection between the tubing connector and the infusion set (cannula part/base piece) and lot 6007389, with no trend identified.Conclusion summary of complaint investigation: as a result of the following: no defect on tests for reference samples, no non-conformance (nc) raised during production related to complaint code, no trend identified for the lot in question and malfunction code, no further actions are required.This complaint will not require further root cause investigation nor capa plan.Therefore, this issue will be monitored through the post market surveillance activities.
|