According to the reporter, during a laparoscopic duodenal perforation, before patient use, the suture was easily detached from the needle swage and could not be used normally.Another suture was used to resolve the issue.There was no patient injury.
|
|
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
|
Additional information: d4 (udi), d9, g3, h3, h6.Correction: a5a, a5b, e1 (facility name, street 1, city, region, country, postal code, fax number and telephone number).H3 evaluation summary: medtronic conducted an investigation based upon all information received.The device was available for evaluation.Visual inspection noted five sutures and five needles.The foil pouch was not returned.The needles were returned disengaged from the sutures.The sutures were returned broken and degraded.Upon microscopic inspection of the needles, normal crimp and swage marks were noted.Three of the needles swages were filled with suture material, indicating the suture broke at the attachment point.Two of the needles swages were free of suture material.It was reported that the needle had detached.The reported issue was confirmed.The most likely cause could not be established from the information available.The evaluation detected an unreported condition: a broken suture.The most likely cause could not be established from the information available.The manufacturing records for each device are thoroughly reviewed prior to release to ensure that it meets all medtronic quality specifications.A secondary review of the device history records found no potentially contributing factors.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|