Model Number REF 316-08
Medical Device Problem Code Gas/Air Leak (2946)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/13/2025
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A theoretical investigation was conducted, as there were no photos and no goods available.No further details have been provided.All cuffs of the tracheostomy cannulas are subjected to a 100% test as part of the quality inspection during production.Leaking products are discarded.However, after an inital use of more than 30 days - longer than the allowed use time - the leaking problem occured.It is therefore confirmed that the product was originally in perfect condition, including a tight cuff-system and a working cuff inflation via the inflation line.It can be assumed that sharp-edged structures in the area of the cuff have led to the leakage during use especially as the end of the application time may have been reached or already exceeded.Nevertheless, the cause cannot be conclusively determined due to the missing goods.
 
Event or Problem Description
1) what went wrong: cuff leak was observed during use after more than 1 month of use, which is more than the allowed duration of use of 29 days.Cuff pressure was tested with manometer and inflation was done with monometer and syringe.The pressure decreases immediately.It is not reported if a priori cuff testing was done and passed.2) health effect: no health effect to the patient reported.The tracheostomy tube with the cuff problem was changed the following day.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRACOE TWIST PLUS TRACHEOSTOMY CANNULA
Common Device Name
TRACOE TWIST PLUS TRACHEOSTOMY CANNULA
Manufacturer (Section D)
TRACOE MEDICAL GMBH
reichelsheimer str. 1/3
nieder-olm, 55268
GM  55268
Manufacturer (Section G)
TRACOE MEDICAL GMBH
reichelsheimer str. 1/3
nieder-olm, 55268
GM   55268
Manufacturer Contact
margarete halle
reichelsheimer str. 1/3
nieder-olm, 55268
GM   55268
MDR Report Key22139949
Report Number8010485-2025-00022
Device Sequence Number18200949
Product Code JOH
UDI-Device Identifier04035324019083
UDI-Public4035324019083
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
K961449
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source User Facility
Initial Reporter Occupation Other
Remedial Action Other
Type of Report Initial
Report Date (Section B) 06/04/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberREF 316-08
Device Catalogue NumberREF 316-08
Device Lot NumberN.A.
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/14/2025
Initial Report FDA Received Date06/04/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-