| Catalog Number |
ERSF-500 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Code |
Unspecified Infection (1930)
|
| Date of Event |
03/26/2025
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
Usa- it was reported that a patient who had a breast surgery augmentation on (b)(6) 2025 was diagnosed with an infection, and the removal surgery was performed on (b)(6) 2025.No patient demographics, such as age, weight, or ethnicity, were provided by the reporter.Efforts to gather additional information are ongoing, and the investigation remains in progress.
|
| |
|
Additional Manufacturer Narrative
|
|
As stated in the literature: ¿the human breast is not a sterile anatomic structure; it contains endogenous flora, derived from the nipple ducts, that is essentially similar to that found in normal skin.Multiple breast ducts provide a passage from the skin surface to deep within the breast tissue" (pittet et al, 2005)."symptoms of infection usually manifest during the first 2 postoperative weeks, but delayed infections may occur months or even years after the operation" (skandalakis, 2009).Per our directions for use, each patient must receive the establishment labs s.A.¿motiva implants®: information for the patient¿ during her surgical consultation, it is the surgeons´ responsibility to ensure that the patient completely understands the information regarding the risks, benefits, and recommendations associated with silicone gel-filled breast implant surgery, as well as the complications typical of any type of surgery.This document is available in motiva® website: ifu.Motiva.Health.The instructions for use in the directions for use were reviewed, to determinate if there are indications that ensure the prevention and good handling of the product.For this event, it is considered that the information is suitable for the section of surgical precautions as follows: infection: "signs of acute infection reported in association with breast implants include edema, erythema, tenderness, pain, and fever.As with other invasive surgeries, toxic shock syndrome (tss), a life-threatening condition, has been reported in rare instances following breast implant surgery.Symptoms of tss occur suddenly and can include high fever (102°f (38.8°c) or higher), vomiting, diarrhea, sunburn-like rash, red eyes, dizziness, lightheadedness, muscle aches, and drops in blood pressure, which may cause fainting.Patients should immediately contact their physician for diagnosis and treatment if any of these symptoms occur." in addition, a review of the device history record was conducted, and it was concluded that there were no deviations in the manufacturing process of this device that would have caused or contributed to this incident.
|
| |
|
Additional Manufacturer Narrative
|
|
General conclusion: device involvement: a causal relationship between the reported event and the device has been established.Event characterization: the event was classified as infection.Clinical confirmation: upon thorough evaluation of the submitted clinical documentation and supporting evidence, the reported case was confirmed.Root cause analysis: this event is a well-documented complication inherent to breast implant surgery.Based on the analysis of the available data, including clinical findings and product traceability records, there is no evidence indicating a causal link between this specific case and any product-related factors, including raw materials or manufacturing processes.The etiology of the alleged event is recognized as multifactorial, given the absence of manufacturing deviations or anomalies, and in line with current clinical literature, the event is considered not attributable to the manufacturing process and/or the product itself.Dfu and labeling evaluation: the event is a known, well-documented complication associated with silicone breast implants.It is clearly addressed in the product¿s directions for use (dfu), which states: "infection ¿ infection can occur with any surgery or implant.Most infections resulting from surgery appear within a few days to weeks after the operation5.However, infection is possible at any time after surgery.In addition, breast and nipple piercing procedures may increase the possibility of infection.Infections in tissue with an implant present are more challenging to treat than infections in tissue without an implant present.If an infection does not respond to antibiotics, the implant may have to be removed, with replacement occurring only after the infection is resolved.As with other surgical procedures, toxic shock syndrome (tss), a life-threatening condition, has been reported in rare instances following breast implant surgery.Tss symptoms occur suddenly and can include high fever (102° f/38.8° c or higher), vomiting, diarrhea, fainting, dizziness, and/or sunburn-like rash.Patients should contact their doctor immediately for diagnosis and treatment if they experience these symptoms." the dfu also emphasizes the responsibility of the surgeon to fully inform the patient of potential risks and complications during the pre-operative consultation.Patients are provided with the document ¿motiva implants®: information for the patient,¿ accessible at ifu.Motiva.Health.Literature reference: the origin of infection in women with implants remains difficult to determine, but potential sources include a contaminated implant, the surgery itself or the surgical environment, the patient's skin or mammary ducts, or, as suggested by many reports, seeding of the implant from remote infection sites.(pittet et al, 2005).¿systemic antibiotic prophylaxis at the time of surgery is associated with a significant reduction of the infection rate (0·42% vs 0·87%) in a large study of 39 455 patients undergoing breast augmentation.¿ (pittet et al, 2005).Several authors suggest that contamination of the prosthesis at the time of insertion may cause a subclinical infection, and thus stimulate a chronic inflammatory response leading to the development of clinically significant capsules (snell & brown, 2009; steiert, boyce & sorg, 2013; wong, 2006).Device history record (dhr) review: a comprehensive review of the device history record (dhr) for the affected lot was completed.No deviations, non-conformances, or anomalies were identified during manufacturing.All raw materials and process parameters conformed to specified quality requirements.Trend and signal monitoring: the event has been evaluated as part of ongoing trend analysis activities within the pms program.Per the current complaint data report: no adverse or unexpected trends related to device rupture have been identified.No further corrective or preventive actions are required at this time.Establishment labs will continue to monitor for similar events as part of routine pms surveillance.
|
| |
|
Search Alerts/Recalls
|
|