| Catalog Number |
VCP316H |
| Medical Device Problem Code |
Material Separation (1562)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
05/06/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Product complaint #(b)(4).H6 component code: g07002 - device not returned.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.A manufacturing record evaluation was performed for the finished device lot, and no non-conformances were identified.The following information was requested, but unavailable: - when did the needle detach or pull off from the suture thread (removal from package / during handling prior to use on patient/ during passage through tissue / during tying / post-op)? - were there patient consequences? if yes, please explain.- please confirm, how many devices demonstrated the alleged deficiency? --received information as following from sales rep via phone today.Please refer to the event description, other information requested is unknown.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that a patient underwent an unknown procedure on (b)(6) 2025 and suture was used.During the procedure, it was reported that the problem of pulling off suture needle happened in surgery.After contacting the manufacturer, it was replied that during the visual inspection of the separated needle, traces caused by surgical tools were noticed in the forging area and holes.Under a magnifying glass, it was observed that there were residual sutures inside the hole.In addition, upon inspection of the suture, it was found that the end cut may have been caused by surgical tools.The user manual includes the following precautions: to avoid such damage, grab the needle in the area from one-third (1/3) to one-half (1/2) of the distance from the connection end to the needle tip.There were no adverse reported.Additional information was requested.
|
| |
|
Search Alerts/Recalls
|
|
|