| Model Number |
102954 |
| Medical Device Problem Code |
Electrical /Electronic Property Problem (1198)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
05/15/2025
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
D4: device serial number and lot number were not provided, and manufacture date (h4) cannot be determined.The primary udi number in d4 is reflective of all available information.No further information provided.A supplemental report will be submitted once the manufacturer investigation is complete.
|
| |
|
Event or Problem Description
|
|
It was reported that the centrimag motor failed on a patient.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrected data: section d5: operator of device corrected.No further information provided.A supplemental report will be submitted once the manufacturer investigation is complete.
|
| |
|
Event or Problem Description
|
|
The patient had become hypotensive and needed to be treated while the perfusion team switched to a backup motor.The patient was removed from extracorporeal membrane oxygenation (ecmo) support a few days later and was transferred to the critical care unit (ccu).The patient passed away a few days later.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer's investigation conclusion: the reported event of the centrimag system unexpectedly stopping was not able to be confirmed.The centrimag console (serial number unknown) was not returned for analysis, and no log files were provided.Attempts were made to obtain additional event information, but no response was received.The root cause of the reported event could not be determined via this investigation.The device history records were unable to be reviewed due to the serial number of the console being unknown.The 2nd generation centrimag system operating manual section 3 "warnings and precautions" warns "one additional 2nd generation centrimag primary console, motor and flow probe are required as backup system in the immediate vicinity of each patient whenever the centrimag or pedivas blood pump is used.The backup console must be connected to the backup motor and to the backup flow probe, have a battery charge sufficient for at least one hour of operation, be connected to ac power (except during transport) and be immediately available should the main console, motor or flow probe experience a malfunction." the 2nd generation centrimag system operating manual section 11.1-"appendix i ¿ console alarms and alerts" contains a list of console alarms and alerts, including s3, m5, m4, and flow-related alarms, as well as appropriate operator response to these events.No further information was provided.The manufacturer is closing the file on this event.
|
| |
|