|
The reported event could not be confirmed.No sample was returned for evaluation.Based on the investigation findings, current manufacturing controls are considered adequate as to detect and segregate any non-conforming unit.Event described could not be confirmed as a manufacturing related issue.The dhr review did not indicate any manufacturing nonconformance that could have caused or contributed to the reported event.The instructions for use were found adequate and states the following: precautions the usual precautions associated with urological procedures should be followed: accepted surgical practice and precautions must be followed for the management of contaminated or infected wound sites, when the align¿ urethral support system is used.Postoperative retropubic bleeding may occur in some patients and must be controlled prior to patient release.The implant procedure requires diligent attention to anatomical structure and care to avoid puncture of large vessels, nerves, bladder, and any viscera, during introducer needle passage.Cystoscopy should be performed to confirm bladder integrity or recognize a bladder perforation.Proper placement of the mesh sling implant at mid-urethra requires that it lies flat with minimal or no tension under the urethra.The align¿ urethral support system is intended as a single-use, disposable device.Do not resterilize any portion of the align¿ urethral support system.Patients should be advised that pregnancy following a mesh sling implant procedure may negatively affect the success of the previous implant procedure and incontinence may reoccur.The safety and effectiveness of the align¿ urethral support system implant procedure has not been established for the treatment of stress urinary incontinence in males or children under the age of 18.Do not use the align¿ urethral support system if the packaging is opened or damaged.After use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and applicable local, state and federal laws and regulations.Adverse events complications associated with the proper implantation of the align¿ urethral support system may include, but are not limited to: postoperative hematoma, which may occur following the implant procedure temporary urinary retention, bladder outlet obstruction, and voiding difficulties associated with over-correction/too much tension placed on the mesh sling implant perforations or lacerations of vessels, nerves, bladder or any viscera, which may occur during introducer needle passage transitory irritation at the operative wound site, which may elicit a foreign body response that leads to inflammation, infection, or erosion of the implant.1750 = l.1928, 1685, 2146, 2123, 1994, 2120, 4861, 2684, 2067, 2275, 1871, 2558, 3274 = nl.Udi format updated with available product information per gudid.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
|
The patient's attorney alleged a deficiency against the device.Additional information has been requested, but not yet received.As per additional information received via medical records on 22may2025, the patient had experienced mesh erosion, stress urinary incontinence, right upper quadrant pain or upper abdominal pain, burning sensation, abnormal vaginal discharge, constant intermittent right foot and ankle pain, urinary tract infections, urethral stone, chronic cholecystitis, sepsis, dysuria, frequency, hematuria, urgency, constipation and required additional surgical and non-surgical treatments.
|