• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ETHICON INC. GYNECARE TVT OBTURATOR W LASR; MESH, SURGICAL, SYNTHETIC, UROGYNECOLOGIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ETHICON INC. GYNECARE TVT OBTURATOR W LASR; MESH, SURGICAL, SYNTHETIC, UROGYNECOLOGIC Back to Search Results
Catalog Number 810081L
Medical Device Problem Code Migration (4003)
Health Effect - Clinical Codes Erosion (1750); Incontinence (1928); Urinary Tract Infection (2120)
Date of Event 04/02/2024
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a patient with a history of pelvic static disorders, first operated on with a tot (tension-free vaginal tape) in 2009 due to stress urinary incontinence.Completion of a promonto-fixation via laparoscopy with mesh for prolapse repair, along with the placement of a new suburethral sling via tot on (b)(6) 2023.The patient quickly experienced a new deterioration in urgency leaks, as well as the emergence of urinary infections.On (b)(6) 2024, re-operated to remove the two strips (tot and tvt) via the vaginal route due to erosion.On (b)(6) 2025, partial removal of the promonto-fixation strip placed in 2023 and placement of a urinary sphincter.Additional information has been requested.
 
Additional Manufacturer Narrative
Product complaint # (b)(4) this report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Please provide the patient's demographic information including age, gender, weight, bmi at the time of index procedure.Other relevant patient history/concomitant medications? onset date/time of the urgency? please provide the onset date/time of urinary infection.Were there any pre-existing signs/symptoms of active infection prior to this surgical procedure? did the patient receive any prophylactic antibiotics pre-, intra- or post-operation? were cultures performed? if so, please provide the results.Please describe any medical intervention performed including medication name and results.When was the mesh exposure first noted by a physician? please provide the mesh exposure site/location, symptoms and diagnostic confirmation.Describe any medical/surgical intervention for the exposure including dates and findings.Were any deficiencies or anomalies noted with mesh device? what is the physician¿s opinion as to the relationship between the tvt mesh and event of prolapse? what is the physician¿s opinion as to the etiology of or contributing factors to the reported events? what is the patient's current status? surgeon¿s name? product code and lot number of tvt implanted in 2009? to date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.H6 component code: g07002 ¿ device not returned.
 
Additional Manufacturer Narrative
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information: h4, h6.A manufacturing record evaluation was performed for the finished device lot number, and no related non-conformances were identified.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GYNECARE TVT OBTURATOR W LASR
Common Device Name
MESH, SURGICAL, SYNTHETIC, UROGYNECOLOGIC
Manufacturer (Section D)
ETHICON INC.
1000 route 202
raritan NJ 08869
Manufacturer (Section G)
ETHICON SARL-NEUCHATEL
puits-godet 20
neuchatel 2000
SZ   2000
Manufacturer Contact
orla o'mahony
1000 route 202
raritan, NJ 08869
3035526892
MDR Report Key22287419
Report Number2210968-2025-07083
Device Sequence Number8310137
Product Code OTN
UDI-Device Identifier10705031062306
UDI-Public(01)10705031062306(17)240531(10)3944543
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K033568
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2024
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 07/16/2025
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date05/31/2024
Device Catalogue Number810081L
Device Lot Number3944543
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/20/2025
Supplement Date Received by Manufacturer07/16/2025
Initial Report FDA Received Date06/18/2025
Supplement Report FDA Received Date07/16/2025
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured06/14/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;